常熟开关CM1系列塑壳断路器选型手册

我***
实名认证
店铺
PDF
3.30MB
约60页
文档ID:133243020
常熟开关CM1系列塑壳断路器选型手册_第1页
1/60

CM 1 系列 塑料外壳式断路器 CM1 SERIES MOULDED CASE CIRCUIT BREAKER 常熟开关制造有限公司 原常熟开关厂 CHANGSHU SWITCHGEAR MFG CO LTD FORMER CHANGSHU SWITCHGEAR PLANT CV系列 CW系列 CM系列 CK系列CR系列CA系列 CJR系列CJD系列CD系列CH系列CE系列 CB系列 S 2011 03 Click to buy NOW P D F X C h a n g e V i e w e r w w w d o c u t r a c k c o m Click to buy NOW P D F X C h a n g e V i e w e r w w w d o c u t r a c k c o m 目录 适用范围 适用工作环境 断路器的分类 CM1快速选用表 脱扣器方式及内部附件代号 四极断路器规格 保护特性 功耗及降容系数 高海拔降容 断路器特性曲线 断路器主要技术性能指标 外形尺寸及安装尺寸 断路器安装安全间隙 内外部附件 接线端子型号 FWB1温度报警模块 使用与维护 订货须知 限流特性 订货规范 1 1 2 3 4 5 6 7 7 8 11 19 37 38 51 52 53 55 55 56 57 59 消防用过载不脱扣只报警接线参考图 不同额定电流的连接导线参考截面 Application range Applicable environment condition Classification of CM1 circuit breakers Table for choosing quickly the CM1 series Release patternand accessories code Specification offour poles breaker Protection feature Power wastage and capacity reducing factor Capacity reducing for high elevation Characteristic curve Main technical performance index Outline dimensions andmounting dimensions Mounting safety clearance Internal external accessories Type of wiring terminal Temperature alarm module Use and maintenance Ordering notice Limited characteristic Ordering form Cross sectionareaof wiring cableandcorrespondingratedcurrent 1 1 2 3 4 5 6 7 7 8 11 19 37 38 51 52 53 55 55 56 57 59 Wiring referential diagram of fire control without release but alarm due to overload Click to buy NOW P D F X C h a n g e V i e w e r w w w d o c u t r a c k c o m Click to buy NOW P D F X C h a n g e V i e w e r w w w d o c u t r a c k c o m CM1系列塑料外壳式断路器 以下简称断路器 是本公司采用国际先进设计 制造技术研制 开发 的新型断路器之一 其额定绝缘电压为800V 适用 于交流50Hz 额定工作电压690V及以下 CM1 63为400V 额定工作电流至800A的电路中作不频 繁转换及电动机保护 CM1 800无电动机保护型 之用 断路器具有过载 短路和欠电压保护功能 能保护线路和电源设备不受损坏 断路器按照其额定极限短路分断能力 Icu 的高 低 分为C型 基本型 L型 标准型 M型 较高分断型 H型 高分断型 四类 该断路 器具有体积小 分断高 飞弧短 部分规格零飞 弧 抗振动等特点 并通过了核工业条件 1E 级 试验和船舶条件的试验 成为国产产品中唯一 能用于核工业基地的产品 更是陆地及船舶使用的 理想产品 本断路器具有隔离功能 其相应的符号为 本断路器产品执行下列标准 IEC60947 2及GB 14048 2 2008断路器 IEC60947 4 1及GB 14048 4机电式接触器和电 动机起动器 IEC60947 5 l及GB 14048 5机电式控制电路电 器 本断路器获国家强制性产品认证 CCC 标志和德 国 TUV 莱茵 公司 CE 认证 本断路器可垂直安装 即竖装 亦可水平安装 即横装 IEC60947 l及GB 14048 1 2006总则 CMl series moulded case breakers hereafter reffered to as simply breakers are one of the new type breakers which have been developed by the company using international advanced design and manufacturing technology The rated insulation voltage of the breakers is 800V suitable for turn on or turn off not frequently and starting a motor not frequently in the circuit of AC50Hz rated working voltage 690V or below CM l 63 is 400V rated working current up to 800A CM1 800 is motor protection free The breakers have overload short circuit and under voltage protection devices so as to protect the circuit and the power equipment against damage The breakers according to the rated maximal valueo short circuit breaking ability Icu would be classified four kinds types C basic type L typica1 type M second high breaking type and H high breaking type The breakers are of the following characteristics compact size high breaking ability short arc over distance some of the0arc over distance and shakeproof They also undergo the tests of nuclear industry conditions 1E grade and ship conditions and become the only product using in nuclear industry base among the same products made in the country furture more become the ideal products applied on land or ships The breakers could beinstalledvertically upright or horizontally transverse The breaker has disconnecting function its corresponding symbol is shown as The breakers comply with the demands of the following standards IEC60947 1 and GB 14048 1 2006General rules IEC60947 2 and GB14048 2 2008circuit breakers IEC60947 4 1 and GB14048 4Electromechanical contactors and motor starters IEC60947 5 l and GBl4048 5Electrical equipments of electromechanica1 control circuit The breaker is permitted to use the CCC marking of CQC and CE marking issued by TUV Rheinland of Germany t 适用范围 适用工作环境 Ambient temperature 5 40 If the temperature is between 40and 60 please see table 7 Elevation2000m Relative humidity not exceeding 50 at the maximum ambient temperature of 40 With lower temperature higher humidity would be permitted but the lowest average temperature in a month not exceeding 25during the most moist moth and the maximum monthly average relative humidity not exceeding 90 in that month and giving consideration to the dews on the goods surface which would appear due to temperature change Pollution protection 3 grade Installing categories for breakers main circuits coils of under voltage release and primary circuit of trainsformers for other auxiliarycircuits and control circuit Be suitable inenvironment A Be able to bear the influence of moisture in the air or salt fog and oil fog or mould or nuclear industry environment The gradient22 5 Be working reliably under the condition of normal vibration on ship Be working reliably when earthquake 4g occuring There must be not any explosive medium and there must be not any g。

下载提示
相似文档
正为您匹配相似的精品文档
相关文档