1、1Instruction ManualAMF PanelPGCON Index1.Introduction22.Features23.Description of Front panel3 4 4.How to start the system55.Description of different display screens6 8 6.Setting parameters and calibration 9 10 7.Precautions112IntroductionThe AMF panel developed by Pankaj Power Solutions Private Lim

2、ited is state of the art; micro controller based technology, and is fully programmable at the site. It is totally different from mechanical or Electro mechanical based AMF panels. It has a user-friendly Man-machine interface with the help of a keypad, LEDs and a LCD display. It has a unique feature

3、of logging the events of DG status and the stored data can directly be transferred to the computer through the Serial COM port.Features1.Real time clock based log of important events.2.Programmable computer Interface.3.Users defined menu driven programmable parameters.4.Scalable Master / Slave confi

4、guration for mission critical applications.5.Online Measurements of Input, Output, DG & Load Parameters.6.man machine inter facing through 4 Line 20 character bright LCD.7.Remote monitoring & A/V alarms in case of fault or abnormality.8.Wide Range of Aux supply, 7 VDC to 60 VDC.9.LEDS for particular

5、 fault indication.10.Electrical & Mechanical interlocking of Mains and DG Contactor for extra safety.3Description of front PanelIt consists of twelve nos. of LED indications, one LCD display and ten switches.1.LEDs IndicationsIf all LEDs are off then all conditions are normal &mains is available. LE

6、D NO.LED STATUS FAULT INDICATION.On (Red)Mains Fail.1. Mains FailOff (White)Mains Available.On (Red)DG 1 Running.Off (White)DG 1 Off.2. DG1/On-OffBlinkingDG 1 Fails.On (Red)DG 2 Running.Off (White)DG 2 Off.3. DG2/On-Off*BlinkingDG 2 Fails.On (Red)DG Alternator Fault.4. ALT FailOff (White)DG Alternat

7、or OK.On (Red)Fuel End.5. Fuel EmptyOff (White)Fuel More then 5%.On (Red)Lube Oil Pressure Low.6. Low LLOPOff (White)Lube OK.On (Red)DG Temperature High.7. DGTMP HighOff (White)DG Temp. NormalOn (Red)DG is unable to start.8. DG STA FailOff (White)DG Starting is OK.On (Red)DG is unable to stop.9. DG

8、STP FailOff (White)DG Stopping is OK.On (Red)Fire / Smoke detected in Canopy.10. FireOff (White)normalOn (Red)Canopy temperature High.11. C TMP HighOff (White)Canopy temp. NormalOn (Red)Fuel is 15 %.42.Switches KEYSFUNCTION OF THE KEYProgram KeyTo see all the screens of the system.Down KeyUsed in ca

9、libration mode, setting the parameters, & in system clock.Up KeyUsed in calibration mode, setting the parameters & in system clock. Enter KeyUsed in calibration mode, setting the parameters & in system clock for entering the selected value .Select DG 1Used in Manual Mode to select DG 1 and in Auto M

10、ode to enter the Password.Select DG 2 Used in Manual Mode to select DG 2 and in Auto Mode to enter the Password.DG StartUsed to start the DG manually in Manual Mode and in Auto Mode to enter the Password.DG StopUsed to stop the DG manually in Manual Mode and in Auto Mode to enter the Password.Fault

11、ACKUsed to Acknowledge the fault.Fault ResetTo Reset the Fault.5How to start the systemTo start the panel, connect the power on the designated terminal provided on rear side of the panel and press fault ack and fault reset switch when the system is initializing.The panel operates in the following mo

12、des: - 1Manual Mode: -To start the DG in this mode press DG 1 select switch and DG start switch.To stop the DG in this mode press DG Stop switch Note: If the DG started in this mode it must be stopped in this mode by pressing the stop switch. Panel will take cooling time to stop the generator after

13、pressing stop switch.2Auto Mode: -In this mode DG will start and stop automatically according to the system conditions.6PANKAJ POWER SOLUTIONS (P) LTD. 01/11/05 10:55:30 LOAD ON MAINSCTMP:25CSBAT:36V WTMP:19CGBAT:12V LUBE:OKFUEL:OK CUM DGRUN:007: 32 Hrs.Description of different LCD screensSCREEN 1Sh

14、ows Date and TimeThe above screen will be in front in normal conditions when the load is on mains.If the load is on mains then the above screen will be in front after a delay irrespective of the earlier screen.SCREEN 2Above screen will appear after pressing the program key once. AbbreviationsDetails

15、CTMPCanopy temperatureIf there is no canopy of DG then it shows the engine temperature.WTMPWater temperatureIf the engine is water-cooled then it shows the temperature of Radiator water and if the engine is air-cooled then it shows the temperature of cylinder of engine.7DG 1 Voltage:230V Load Curren

16、t:006 A Fuel: OKLube:OK RPM: 1500Hr:01:32LUBELubricant Oil statusIf DG is OFF then it will show Lube Fault but when the DG is in running Lube pressure must be OK to run DG continuously. SBATSystem enabling parameter If enabling parameter is more than low Sys bat, set in setup parameters then the DG will not start in auto mode when mains fail.GBATGenerator Battery (Self Start)Generator self-start battery (12V) must be more than the low generator battery set in setup par