日本胶合板标准

上传人:kms****20 文档编号:46537904 上传时间:2018-06-27 格式:PDF 页数:78 大小:803.66KB
返回 下载 相关 举报
日本胶合板标准_第1页
第1页 / 共78页
日本胶合板标准_第2页
第2页 / 共78页
日本胶合板标准_第3页
第3页 / 共78页
日本胶合板标准_第4页
第4页 / 共78页
日本胶合板标准_第5页
第5页 / 共78页
点击查看更多>>
资源描述

《日本胶合板标准》由会员分享,可在线阅读,更多相关《日本胶合板标准(78页珍藏版)》请在金锄头文库上搜索。

1、 1 Japanese Agricultural Standard for Plywood Establishment: Notification No. 233, February 27, 2003, Ministry of Agriculture, Forestry and Fisheries Last Amendment: Notification No. 1751, December 2, 2008, Ministry of Agriculture, Forestry and Fisheries Note:This is an unofficial translation, for y

2、our reference only. (Scope of Application) Article 1 This standard shall apply to the products those having at least 3 layers of veneers (including the small square lumber for core layers) sliced using a rotary lathe or a slicer and bonded together placing the grain direction almost perpendicular to

3、 each other (hereinafter, referred to as “plywood”). (Definitions) Article 2 In this standard, the definition of the terms listed in the left column of the following table shall be those shown in the respective right column of the same table. Term Definition Plywood for General Use Among plywood pro

4、ducts, plywood except for Concrete Forming Plywood, Structural Plywood, Natural Wood Decorative Plywood and Specially Processed Decorative Plywood. Concrete Forming Plywood Among plywood products, plywood used for the frame to form concrete to a specific shape (including those with paint or overlay

5、applied on the surface or the surface and back (hereinafter, referred to as surface processed concrete forming plywood). Structural Plywood Among plywood products, plywood to be used for the principal structural members of buildings (including those with tongueandgroove finish). Natural Wood Decorat

6、ive Plywood Among plywood products, plywood with the veneers bonded on the surface or the surface and back mainly for the purpose of aesthetic appearance of natural wood material. Specially Processed Decorative Plywood Among plywood products, plywood except for Concrete Forming Plywood and Natural W

7、ood Decorative Plywood, having the special processing such as overlay, print and paint is applied on the surface or the surface and back. Type Special Type of plywood to be used outdoor or in the sections where constantly exposed to wet sections (environment) and which meets the requirement of Bondi

8、ng Quality in Item 1 of the next Article. Type I Concrete Forming Plywood and type of plywood to be used in the sections where intermittently exposed to wet conditions (environment) and which meets the requirement of Bonding Quality in Item 2 of the next Article. Type II Type of plywood to be used i

9、n the sections where occasionally exposed to wet conditions (environment) and which meets the requirement of Bonding Quality in Item 3 of the next Article. F Type Specially Processed Decorative Plywood mainly used for table top, counter, etc. FW Type Specially Processed Decorative Plywood mainly use

10、d for bearing wall of building, as well as for furniture. W Type Specially Processed Decorative Plywood mainly used for general wall of building. SW Type Specially Processed Decorative Plywood mainly used for special wall of building. 2 (Bonding Quality) Article 3 Criteria for the bonding quality of

11、 plywood shall be as follows: 1. For Type Special, the plywood product shall meet the requirement of either (1), (2) or (3) (limited to those consist of softwood veneers only) of all of the followings: (1) As the results of Continuous Boiling Test specified in 3(2) of the Appendix, the average wood

12、failure ratio and shear strength shall be not less than the values provided in Table (1). In this case, for layers with its fiber direction mostly parallel to that of the adjacent veneers (hereinafter, referred to as parallel layer), the length of nondelaminated portion on the same bonding layer of

13、the specimen shall be not less than 2/3 of the length of each side. (2) As the results of Cyclic Steaming Test specified in 3(2) of the Appendix, the average wood failure ratio and shear strength shall be not less than the values provided in Table (1). In this case, for the parallel layers, the leng

14、th of nondelaminated portion on the same bonding layer of the specimen shall be not less than 2/3 of the length of each side. (3) As the results of Vacuum Pressure Test as specified in 3(2) of the Appendix, the specimens shall meet the following conditions from a. to c. In this case, for the paralle

15、l layers, the length of non delaminated portion on the same bonding layer of the specimen shall be not less than 2/3 of the length of each side. a. The average wood failure ratio of all test specimens shall be not less than 80%. b. The number of test specimens with the wood failure ratio of 60% or g

16、reater shall be not less than 90%. c. The number of test specimens with the wood failure ratio of 30% or greater shall be not less than 95%. 2. For Type I, the plywood product shall meet the requirement of either (1), (2) or (3) (limited to Concrete forming plywood consists of softwood veneers only) of all of the followings. However, for Surface processed concrete forming plywood, Natural wood decorative plywood

展开阅读全文