《丹佛斯fc300系列变频器参数讲解资料》由会员分享,可在线阅读,更多相关《丹佛斯fc300系列变频器参数讲解资料(149页珍藏版)》请在金锄头文库上搜索。
1、1,2,参数表,安装 编程 参数 0-* 操作和显示 1-*负载和电机 2-*制动 3-*参考值/加减速 4-*限制/警告 5-*数字输入/输出 6-*模拟输入/输出 7-*PID控制器 13-*智能逻辑控制器 14-*特殊功能 15-*变频器信息 16-*数据读出 17-*编码器,警告(WARNING)和报警(ALARM) 选件和附件,3,Installation,Mechanical Installation,Back to content,4,Installation,Mechanical Installation,Back to content,5,外壳类型,Mechanical In
2、stallation,Back to content,6,Installation,Electrical Installation,强电端子,电机端子,电源端子,制动及负载共享,继电器,LC滤波器,外部24V供电,Back to content,7,Installation,Electrical Installation,Controlteminals,Back to content,8,Installation,Electrical Installation,Tension spring technology,接线,拆线,连接,Back to content,9,Installation,E
3、lectrical Installation,Control Terminal Diagram,Back to content,10,Installation,Electrical Installation,Back to content,11,Installation,Electrical Installation,开关 S201, S202, and S801 开关 S201 (A53) 、 S202 (A54) 用来选择53/54端子的电流 (0-20 mA) 或电压输入(-10 to 10V) 开关 S801 (BUS TER.) 是 RS-485 口的终端电阻开关 (terminal
4、s 68 and 69). 默认值: S201 (A53) = OFF (电压 input) S202 (A54) = OFF (电压 input) S801 (终端电阻) = OFF,断电状态下拨动开关, 拨动时最好摘下面板的底托, 小心用力!,Back to content,12,暗,Status,显示亮度,Programming,Operating Instruction,恢复出厂值,按住同时上电,保持5秒 (or P.14-22),Or press for 3s,快捷 (direct access),Main Menu,Main Menu,-Key,1 x pushing - last
5、 changed Parameter 2 x pushing - Mainmenu,Important settings:,Back to content,13,Programming,Quick Menu,Back to content,14,Programming,Menu Structure,Back to content,15,Programming,Example,2-0*DC-Hold / DC . 2-1*Overvoltage 2-2*Mech. Brake,Brakefunctionen,16-0*Readout-All 16-1*Readout-M 16-3*Readout
6、 F 16-5*Readout-S,Date readouts,Back to content,16,Programming,Array Parameter,Array Number,Array Value,Back,Back,Cancel,or,Ok,or,Array Input,Back to content,17,Parameters Operation and Display,Group 0 Operation and Display,0-01 Language,Value:,*English (ENGLISH) 0 German (DEUTSCH) 1 French (FRANCAI
7、S) 2 Danish (DANSK) 3 Spanish (ESPANOL) 4 Italian (ITALIANO) 5 Swedish (SWEDISH) 6 Dutch (DUTCH) 7 Chinese (CHINESE) 10,Finnish (FINNISH) 20 English US (ENGLISH US) 22 Greek (GREEK) 27 Portuguese (PORTUGUESE) 28 Slovenian (SLOVENIAN) 36 Korean (KOREAN) 39 Japanese (JAPANESE) 40 Turkish (TURKISH) 41
8、Traditional Chinese 42 Bulgarian 43,Serbian 44 Romanian (ROMANIAN) 45 Hungarian (HUNGARIAN) 46 Czech 47 Polish (POLISH) 48 Russian 49 Thai 50 Bahasa Indonesian (BAHASA INDONESIAN) 51,0-0* Operation / Display Parameters related to the fundamental functions of the frequency converter, function of the
9、LCP buttons and configuration of the LCP display. 0-0* Basic Settings Parameter group for basic frequency converter settings.,Back to content,18,Parameters Operation and Display,Group 0 Operation and Display,0-02 Motor Speed Unit,Value:,* RPM 0 Hz 1,Select display of motor speed parameters (i.e. ref
10、erences, feedbacks and limits) in terms of shaft speed (RPM) or output frequency to the motor (Hz).,Back to content,0-03 Regional Settings,Value:,* International 0 US 1,Select International 0 to set par.1-20 Motor Power units to kW and the default value of par. 1-23 Motor Frequency to 50 Hz. Select
11、US 1 to set par.1-21 Motor Power units to HP and the default value of par. 1-23 Motor Frequency to 60 Hz.,19,Parameters Operation and Display,Group 0 Operation and Display,0-10 Active Set-up,Value:,0-1* Set-up Operations Define and control the individual parameter setups.,Factory setup 0 * Set-up 1
12、1 Set-up 2 2 Set-up 3 3 Set-up 4 4 Multi set-up 9,Select the set-up to control the frequency converter functions. Factory Set-up 0 cannot be changed. It contains the Danfoss data set, and can be used as a data source when returning the other set-ups to a known state. Set-up 1 1 to Set-up 4 4 are the
13、 four separate parameter set-ups within which all parameters can be programmed. Select Active Set-up 9 for remote selection of set-ups using digital inputs and the serial communication port. This set-up uses the settings from par. 0-12 This option linked to. Stop the frequency converter before makin
14、g changes to open loop and closed loop functions. Use par. 0-51 Set-up copy to copy a set-up to one or all other set-ups.,Stop the frequency converter before switching between set-ups where parameters marked not changeable during operation have different values. To avoid conflicting settings of the
15、same parameter within two different setups, link the set-ups together using par. 0-12 This set-up linked to. Parameters which are not changeable during operation are marked FALSE in the parameter lists in the section Parameter Lists.,Back to content,20,Parameters Operation and Display,Group 0 Operat
16、ion and Display,0-11 Edit Set-up,Value:,Select the set-up to be edited (i.e. programmed) during operation; either the active set-up or one of the inactive set-ups. Factory set-up 0 cannot be edited but it is useful as a data source to return the other set-ups to a known state. Set-up 1 1 to Set-up 4 4 can be edited freely during operat