1、EMC CLARiiON 安装及配置安装及配置EMC CLARiiON安装与配置安装与配置2CLARiiON安装配置安装配置1.Gather Network Information2.Verify Power Supply Settings3.Confirm the Standby Power Supply(SPS) Connections4.Start The FC47005.Initialize the FC47006.Connect a Management Station7.Configure The FC47008.Make Switch And Host Connections9.

2、Setup The Hosts10.Creat The FC4700 Storage Group11.Complete The Host Setup12.Setup SnapView And MirrorView SoftWare13.Setup Event MonitorEMC CLARiiON安装与配置安装与配置3Before You Start1.Confirm that electrical wiring is in place at your facility to accommodate the cabinets two 240-volt ac power cables. To s

3、upport all of the FC4700 high-availability features, you must connect each power distribution unit to a different circuit.2. Verify that your facility has adequate network wiring for your sub-network (subnet) connections. To manage the storage system, each storage processor (SP) requires a separat n

4、etwork connection.EMC CLARiiON安装与配置安装与配置43. If your environment includes switches on the path between the FC4700 and the hosts (servers) that have access to it, make sure the switches are installed. Refer to the device-specific installation manuals for each switch.4. Verify that the Standby Power Su

5、pplies (SPSs), Disk Processor Enclosure (DPE), and any optional Disk Array Enclosures(DAEs) are installed in your cabinet. If necessary, refer to the appropriate cabinet, rail, or device hardware installation documentation you received with your system.Before You StartEMC CLARiiON安装与配置安装与配置55. Have

6、the network administrator at your facility set up IP addresses for the FC4700 6. Make sure that the latest revisions of Navisphere Manager and Event Monitor are installed on the Windows 2000 or Windows NT host you will use as the Navisphere management station. Before You StartEMC CLARiiON安装与配置安装与配置6

7、 SP-A SP-BHostname _ _Up to 15 alphanumeric characters. Dashes are acceptable.Special characters such as dots, spaces, or underscores arenot allowed. Examples: Array1-A, Array1-B.IP Address _ _Subnet Mask _ _Gateway _ _Step 1 Gather Network InformationEMC CLARiiON安装与配置安装与配置7Step 2 Verify Power Suppl

8、y Setting1.Remove the disk drive fan pack.2. Confirm that the power switch on each power supply behind the fan pack is on, then replace the fan pack.EMC CLARiiON安装与配置安装与配置8Step 3 Confirm the Standby Power Supply Connection 1. Standby power supply A (SPS-A) connects to the lower serial port (COM2) of

9、 SP-A.2. Standby power supply B (SPS-B) connects to the lower serial port (COM2) of SP-B.EMC CLARiiON安装与配置安装与配置9Step 4 Start FC47001. Plug the two 240-volt ac power cables into the power outlets in your facility. We recommend connecting each power cable to a different branch circuit. Connecting only

10、 one power source will degrade the FC4700s performance.EMC CLARiiON安装与配置安装与配置102.Turn on the circuit breakers on each of the cabinets side power strips.3. Turn on the power switch on each standby power supply.If warning lights appear on the front of the DPE, make sure the system is correctly cabledS

11、tep 4 Start FC4700EMC CLARiiON安装与配置安装与配置11Step 5 Initalize The FC4700 Initializing the FC4700 requires a directly connected computerusually a laptop model that we refer to as a service laptop. IMPORTANT The following guidelines outline how experienced technical personnel initialize an FC4700 storage

12、 system. EMC CLARiiON安装与配置安装与配置12Service Laptop Setup1. Connect the service laptop to the serial port on SP-A with the null modem cable.2. Make sure Dial-Up Networking between 2 PCs is installed and set up on the service laptop.3. Set up Dial-Up Networking.4. Modify the laptops TCP/IP network settin

13、gs to use DHCP.Step 5 Initalize The FC4700EMC CLARiiON安装与配置安装与配置13Critical Parameter SetupOn the FC4700:5. Set up a user account.6. Create the Persistent Storage Management (PSM) LUN.7. Specify privileged users for the FC4700.8. Set the SPS test time for each SPS in your system.Step 5 Initalize The

14、FC4700EMC CLARiiON安装与配置安装与配置14Network Information Setup9. Specify the hostname, IP address, subnet mask, and gateway address for SP-A. Use the information you collected and entered earlier in Step 1, Gather Network Information.10.Disconnect the service laptop from SP-A and connect it to the serial p

15、ort on SP-B.11.Specify the hostname, IP address, subnet mask, and gateway address for SP-B. Step 5 Initalize The FC4700EMC CLARiiON安装与配置安装与配置15SP ALPHA SCSI ID Setup12.Use Navisphere Manager to select each FC4700-2 SP Agent to be managed.13.Set the ALPHA SCSI ID value for each port on SP-A and SP-B.

16、14.Set the desired FC speed for each port on SP-A and SP-B.Setup Confirmation15.Make certain all software packages are committed. In Navisphere Manager, check the Software tab of the Array Properties selection for any software packages requiring a COMMIT. Step 5 Initalize The FC4700EMC CLARiiON安装与配置

17、安装与配置16Step 6 Connect a Management Station Connect each SP separately to the LAN to which your Navisphere management station is connected.EMC CLARiiON安装与配置安装与配置17Step 7 Configure The FC4700 System1. Select the FC4700 storage system you want to configure. Optional FC4700 Software Installation2. If yo

18、u have the Access Logix software, install it with a nondistruptive installation (NDU). If you have SnapView or MirrorView software, install them in a subsequent NDU. Refer to the option-specific documentation as appropriate. Make certain all software packages are committed. In Navisphere Manager, ch

19、eck the Software tab of the Array Properties selection for any software packages requiring a COMMIT. Perform the commit if necessary.EMC CLARiiON安装与配置安装与配置18Remote SP Agent Configuration3. Specify any additional privileged users for each SP. Storage-System Properties Setup4. Set the general configur

20、ation properties enable automatic polling, automatic polling priority, and SP-A and SP-B statistics logging.5. Set the read and write cache memory properties for each SP.6. Set the FC4700 cache properties.7. If the FC4700 is running Access Logix, set the data access property.Step 7 Configure The FC4

21、700 SystemEMC CLARiiON安装与配置安装与配置191.Remove the protective covers from each optical connector and cable.2. Plug the cables into the SP host ports.3. Connect the other end of the Port 0 (top) cable as follows: For a direct attach configuration to the host servers host bus adapter . NOTE If the HBA is

22、not yet installed in the host server, complete Step 9, then connect the SP.Step 8 Make Switch or Host ConnectEMC CLARiiON安装与配置安装与配置204. Connect the other end of the Port 1 (bottom) cable as follows: In a system without MirrorView to an HBA port (directattach configurations) or switch port (SAN confi

23、gurations) In a system with MirrorView to a storage processor (SP) host port on the remote storage system.Step 8 Make Switch or Host ConnectEMC CLARiiON安装与配置安装与配置21Step 9 Setup the HostHBA and Driver InstallationComplete the following tasks on each host that will use the storagesystem.1. Install the

24、 host bus adapters (HBAs) in the host. Refer to the EMC Fibre Channel HBA and Driver Installation Guide and EMC Fibre Channel HBA/Driver Release Notesappropriate for your operating system.2. For a SAN configuration, connect each HBA to the appropriateswitch port.3. For a direct attach configuration,

25、 connect each HBA to theappropriate SP port.4. Install the HBA driver and any utilities from the HBA media (ifappropriate) on each host.EMC CLARiiON安装与配置安装与配置225. Switch Zone Creation Refer to the device-specific documentation provided with your Fibre Channel switch(es) to complete the following:6.

26、On each switch fabric, create a zone for each HBA and all the SP ports that you want the HBA to access. Use World Wide Port Names (WWPNs) to specify the HBA and the SP ports for the zone.Step 9 Setup the HostEMC CLARiiON安装与配置安装与配置23HBA and Driver Installation (continued)7. Install CLARiiON Driver Ex

27、tension (CDE) software if CDE is available for your host, and your configuration requires it. FC4700 storage systems support CDE in IBM AIX, Sun Solaris, and Microsoft Windows NT and Windows 2000 environments. Configurations with only one host HBA require CDE.8. Activate the driver. Depending on the

28、 host, you may need to reboot the host.Step 9 Setup the HostEMC CLARiiON安装与配置安装与配置24Navisphere Host Software Installation1. If the host has multiple HBAs connected to the storage system and Navisphere Application-Transparent Failover (ATF) is available, install ATF. FC4700 storage systems support AT

29、F in AIX, Novell Solaris, Windows NT and Windows 2000 environments.2. Install the Navisphere Host Agent and optional CLI.3. Activate the ATF devices and Host Agent by rebooting the host.4. If you plan to install SnapView software, install the admsnap host management utility software.Step 9 Setup the

30、 HostEMC CLARiiON安装与配置安装与配置25Step 10 Create FC4700 Storage Group1.Create a RAID Group1)Right-click storage system.2)Select “Create RAID Group” in menu.3)Choose either basic or advanced dialog.4)In advanced dialog, disks can be selected manually.EMC CLARiiON安装与配置安装与配置262. Bind a LUN In a RAID GroupSt

31、ep 10 Create FC4700 Storage Group1)Right-click storage system icon.2)In menu, select “Bind LUN”.3)Choose basic or advanced bind dialog.4)Select options and click “Apply”.EMC CLARiiON安装与配置安装与配置273.AccessLogixStep 10 Create FC4700 Storage GroupUse “Detailed View” to get an overview of the Access Logix

32、 setup.Select “Detailed View” from the right-click menu for the storage system.All icons are active.EMC CLARiiON安装与配置安装与配置284. Turning On Access Logix using Navisphere ManagerStep 10 Create FC4700 Storage Group1)Right-click storage system icon and select “Properties”.2)Go to “Data Access” tab.3)Chec

33、k the “Access Control Enabled” checkbox.4)Click “OK”.5)Cannot be unchecked!EMC CLARiiON安装与配置安装与配置295. Creating and destroying Storage Groups using ManagerStep 10 Create FC4700 Storage Group1)Right-click storage system icon and select “Create Storage Groups”.2)Specify name for storage group.3)Move LU

34、Ns to the “Selected LUNs” area.4)Check whether SG should be dedicated or sharable.EMC CLARiiON安装与配置安装与配置306. Connecting Hosts Using Navisphere ManagerStep 10 Create FC4700 Storage GroupFind storage group in “Storage Groups” folder in “Storage” tab.Right-click SG and select “Connect Hosts”.Move hosts

35、 between areas.Click “OK” or “Apply”.EMC CLARiiON安装与配置安装与配置317. Changing Storage Group Settings Using Navi ManagerStep 10 Create FC4700 Storage GroupRight-click storage group icon and select “Properties”.Make changes in the property dialog.Click “OK” or “Apply”.EMC CLARiiON安装与配置安装与配置328. Adding or R

36、emoving LUNs from Storage Group using ManagerStep 10 Create FC4700 Storage Group1)In property dialog for storage group, click “Select LUNs”.2)Move LUNs between the two areas.3)Click “OK”.4)Click “OK” again in properties dialog.EMC CLARiiON安装与配置安装与配置33Step 11Complete the Host Setup Refer to the appro

37、priate EMC Navisphere Server Software Setup Guideto complete the following for each host that will use the storage system.1. Make the LUNs for each host available to the hosts operating system. Depending on the operating system, this may involve: Labeling and partitioning LUNs Making file systems or

38、 creating volumes on the partitions Mounting the file systems or volumes.2. If hosts are clustered, set up the clustering software to work with the FC4700-2.click sessionSelect “Properties.”EMC CLARiiON安装与配置安装与配置34CLARiiON CX600Initializing the CX600 With Navisphere 6.1EMC CLARiiON安装与配置安装与配置35Overvi

39、ewConfiguration steps similar to FC4700 with Navisphere 6.05 (no PSM setup)Service Laptop Requirements:Windows NT or Windows 2000Internet Explorer 5.5 or Netscape 6.0Java Runtime Environment 1.3.1_01Navisphere 6.1 Management UI (new)Serial PPP ConnectionSerial CableEMC CLARiiON安装与配置安装与配置36Initializi

40、ng the CX600Configure the Service LaptopSet the Storage Processor TCP/IP Parameters for SP-A and SP-BSet the Array Date and TimeConfigure Operating ParametersCommit Base SoftwarePerform NDU to Upgrade or Add Optional Software ComponentsConfigure Read/Write CacheCreate RAID Groups, Storage Groups, Bi

41、nd LUNs, and Connect HostsEMC CLARiiON安装与配置安装与配置37Configuring the Service LaptopInstall the required Service UI Navisphere softwareJava 1.3.1_01Navisphere 6.1 Windows UINavisphere CLICreate a Windows dial-up networking PPP connectionEMC CLARiiON安装与配置安装与配置38Configure SP-A IP ParametersConnect serial

42、cable to SP-AEstablish a PPP network connection to SP-AOpen Internet browser to: http:/192.168.1.1/setupSet network properties for SP-AIP Address, Hostname, Subnet Mask, Gateway, Peer IP AddressApply settings (SP-A reboots)Disconnect serial cable from SP-AEMC CLARiiON安装与配置安装与配置39Storage Processor Ne

43、twork Setup Via Serial PPP SessionEMC CLARiiON安装与配置安装与配置40Configure SP-B IP ParametersConnect serial cable to SP-BEstablish a PPP network connection to SP-BOpen Internet browser to: http:/192.168.1.1/setupSet network properties for SP-BIP Address, Hostname, Subnet Mask, Gateway, Peer IP AddressApply

44、 settings (SP-B reboots)Disconnect serial cable from SP-BEMC CLARiiON安装与配置安装与配置41Restart SP-As Management ServerRe-connect the serial cable to SP-AEstablish PPP session to SP-AOpen Internet browser to: http:/192.168.1.1/setupClick Restart Management ServerCheck Yes to restart the Management ServerWa

45、it 60 Seconds for the Management Server to restartDisconnect the serial cableEMC CLARiiON安装与配置安装与配置42Restarting Management ServerEMC CLARiiON安装与配置安装与配置43Configure Operating ParametersAttach Service Laptop Ethernet ConnectionBrowse to the directory where the Navisphere 6.1 Windows UI was installed an

46、d double-click on start.html When Java starts, click “Grant Always”Enter the IP address of the SP to connect toOptionally configure Storage Domain SecurityOpen the Properties Page for the arraySet the Date & Time for the arraySet FC port speeds (1G or 2G for each SP, 2G Default)Configure privileged

47、users for the SP AgentSet ALPAs (Not required, FC Hubs not supported)Commit the Base softwareEMC CLARiiON安装与配置安装与配置44Configuring Storage Domain SecurityEstablish Storage Domain Master (either SP-A or SP-B)Establish Storage Domain Name (default name: DomainDefault)Establish other Storage Domain user

48、accounts (optional)Reset Storage Domain security (via serial PPP session) performed to remove all securityEMC CLARiiON安装与配置安装与配置45Initializing Storage Domain Security Via Navisphere Windows UIEMC CLARiiON安装与配置安装与配置46Initializing Storage Domain Security Via Serial PPP SessionEMC CLARiiON安装与配置安装与配置47C

49、onfigure Operating ParametersPerform a NDU to install any updates or optional software onto the arrayManagement UI, Access Logix, SnapView, MirrorViewConfigure Read/Write CacheEnable Access Logix and Fair Access (if required)Create RAID Groups and Bind LUNsCreate Storage Groups (Access Logix)Attach HostsEMC CLARiiON安装与配置安装与配置48部分资料从网络收集整理而来,供大家参考,感谢您的关注!