住宅小区配电设计外文文献翻译中英文

上传人:ni****g 文档编号:488251342 上传时间:2024-02-12 格式:DOC 页数:30 大小:63KB
返回 下载 相关 举报
住宅小区配电设计外文文献翻译中英文_第1页
第1页 / 共30页
住宅小区配电设计外文文献翻译中英文_第2页
第2页 / 共30页
住宅小区配电设计外文文献翻译中英文_第3页
第3页 / 共30页
住宅小区配电设计外文文献翻译中英文_第4页
第4页 / 共30页
住宅小区配电设计外文文献翻译中英文_第5页
第5页 / 共30页
点击查看更多>>
资源描述

《住宅小区配电设计外文文献翻译中英文》由会员分享,可在线阅读,更多相关《住宅小区配电设计外文文献翻译中英文(30页珍藏版)》请在金锄头文库上搜索。

1、外文文献翻译 (含:英文原文及中文译文)译文字数:3700多字 文献出处: J Ehnberg. Power of Community Distribution to DesignJ Value Engineering, 2016, 2(3):14-21英文原文 Power of Community Distribution to DesignJ EhnbergABSTRACTThe basic function of the electric power system is to transport the electric power towards customers. The l0kV

2、 electric distribution net is a key point that connects the power supply with the electricity using on the industry, business and daily-life. For the electric power, allcostumers expect to pay the lowest price for the highest reliability, but dont consider that its self-contradictory in the co-exist

3、ence of economy and reliable.To improve the reliability of the power supply network, we must increase the investment cost of the network construction But, if the cost that improve the reliability of the network construction, but the investment on this kind of construction would be worthless if the r

4、educing loss is on the power-off is less than the increasing investment on improving the reliability .Thus we find out a balance point to make the most economic,推荐精选 between the investment and the loss by calculating the investment on power net and the loss brought from power-off.KEYWORDS: power sup

5、ply and distribution, power distribution reliability , reactive compensation, load distributionIn general, major changes to the building include: high voltage and low voltage distribution systems, transformers, and backup power systems. Power systems include power distribution and control, indoor an

6、d outdoor lighting systems include all types of lighting, and lightning protection systems include intrusion protection, lightning sensors, grounding, equipotential bonding, and local equipotential bonding. Auxiliary equipotential bonding. In just 20 years, the system has undergone enormous changes

7、in the face of technology and products. Many design ideas have also changed dramatically. Switchgear, such as the first circuit-breaker oil circuit breaker in a high-voltage system, and the subsequent development of an oil circuit breaker, are not only large in size but generally contain oil. Due to

8、 the large size of the switchgear, we must also establish a separate equipment room that occupies a large amount of floor area. Vacuum circuit breakers and sulfur hexafluoride circuit breakers are not only small in size, but also have a large short-circuit capacity. The size of the housing is much l

9、arger than that of the original cabinets, and the circuit breakers do not have any oil and the fire performance is greatly improved. And circuit breakers and other low-voltage devices are in one room, which saves space and is easy to manage. In the past, large-capacity low-voltage circuit breakers g

10、radually increased the capacity of the short-circuit current, gradually reduced the scale, and became more stable, making the system safer and more reliable, which facilitated the design. Towards the development of intelligent low-voltage circuit breakers, various parameters of the circuit breaker c

11、an be controlled by the bus industry and the signals are transmitted directly to the computer.推荐精选The appearance of dry-type transformers has brought great convenience to the electrical design of buildings because there is no possibility of leakage of transformer oil and fire so that it can be easil

12、y installed in the building itself and even directly into the load center. It also eliminates the transformers demand for oil and can use dry-type transformers when building large-capacity equipment. Four Taiwanese 2500kVA dry-type transformers have been used in actual engineering design.推荐精选In term

13、s of using emergency generators, it is much more advanced than in the past in terms of performance and size. In addition to using diesel generators; emergency lighting uses EPS standby power; devices that interrupt power within a millisecond can use UPS.The control of electrical equipment varies fro

14、m the control of a single component to the control of relays. In addition to the smaller size of the various components for better performance, the specification of the control box is also reduced. Because digital technology is more used in control to achieve the best control status to control the e

15、quipment. Further improve the effect of energy conservation.The revolution of electric power system has brought a new big round construction, which is pushing the greater revolution of electric power technique along with the application of new technique and advanced equipment. Especially, the combin

16、ation of the information technique and electric power technique, to great ex- tent, has improved reliability on electric quality and electric supply. The technical development decreases the cost on electric construction and drives innovation of electric network. On the basis of national and international advanced electric knowledge, the dissertation introduces the research hotspot推荐精选 for present electric power syetem as following.Firstly,

展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 资格认证/考试 > 自考

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号