1、Construction:Hot knife edge for webbing ends and guy line endsCapture a minimum 1.3 cm (0.5 in) webbing in seamStitches per inch: Minimum ?6; Maximum ?8All lap-felled, inverted and bounded seams shall have two rows of stitching.Seam Allowance 1.3 cm (0.5 in) on all sewn seamsBackstitching 1.5 cm (0.

2、59 in) mandatory at end of all sewn seamsBar Tack or backstitch: -body: of tent: pin & ring web loops -rainfly:corner web attachment, guy line web attachmentsFloor:Inverted seams with Polyester Bindings Heat/pressure seams on floor; 2.5 cm (1 in) overlapCorners and all ground level stitching to be w

3、elded. All welds shall be fully bonded without loose edges.(Refer to Section 8 for Corner Weld Reinforcement details)Reinforcement for corner welds: A piece of V shaped PE reinforcement material shall be added to each corner weld when attaching stake webbing to welded corners as shown in Section 8 -

4、 Pin & Ring System - Pin & Ring to PoleAll guy out loops shall have guy out triangle reinforcement when attached to rainfly(Refer to Section 8 for GuyOut Triangle Construction details)Door Zipper cuff: Apply trim to the outside edge of all zipper cuffs. All zipper cuffs shall lay flat against zipper

5、s. The length of zipper cuff shall be adequate to shield zippers from a 30 degree slanted rain shower(Refer to Section 8 for Door Zipper Cuff Height details)Toggle/Loop for door to be assembled with Toggles outside & Loops to be sewn inside of tentZippers to be installed with teeth facing inside the

6、 tentCool Air Port & Electrical Port: Seam taped seams as shown in Section 8When installing zipper for electrical port the ends of zipper tape shall not be sewn directly into wall seam(Refer to Section 8 for Electrical Port Zipper Tape details)Pocket will be made of mesh trimmed with fabric. 1.1 A-M

7、ajor (AQL = 0.0 )This classification includes defects that could cause serious injury, that are unsafe, hazardous, or illegal. Products that are misbranded or not in the correct packaging or incorrect, unscannable or missing bar code or part numbers are also included.1.1.1All Bar Codes on packaging

8、and literature will be correct.Product will not be missing or have incorrect Bar Code or part number. Bar Code(s) will be scannable and will match the part number, UPC code and I2of5 code shown in Supply Chain Data.Point of Sale (POS) package bar code or hang tag bar code willscan as UPCA format.(No

9、te: POS & hang tag may not always be applicable to every unit.Refer to Section 6 for type of packaging and POS marking.)Master Carton bar code will scan as I 2 of 5 format.1.1.2Product will be in the correct Coleman?packaging per Section 6.0.Packaging will represent the product accurately.Country of

10、 origin will be printed on the Point of Sale (POS) package.1.1.3Product will be marked with country of origin as specified in Section 5.0.Visual Inspection.1.1.4Product will pass Sharp Edge Test:If a non-functional sharp edge is found to be in question, the sharp edge test per ASTM F963-96A, Interte

11、k ETL Standard or Underwriters Laboratories (UL) 1439 will be performed.Any sharp edge that fails the test will be an A-major defect.1.1.5Warning label will be included as indicated per Section 3.3 (05):Warning label will be permanently attached and will be legible with information indicated in Sect

12、ion 5.3.Part Number, Country of Origin & Date Code will be included on warning label.1.1.6Warning Information on Point of Sale Packaging:Visual inspection.Warning information as stated in Section 6 will be included on POS packaging.1.2 Functional (AQL = 1.0 )This classification includes defects that

13、 cause the product or package not to function as intended.1.2.1Packaging will contain product securely:Packaging will protect and contain the product securely. Packaging that is not saleable will be a functional defect. (for example, bulging package, open seams, etc.)Bulging Package to be defined as

14、 boxed package that will not lay flat on all sides due to sides bowing out.1.2.2Product Packaging:Product will be packaged per Special Requirements if detailed inSection 6.4 & 6.5.1.2.3Setup System:Pole styles will match tent style for set up system (for example, Pole Talon?with open end tent poles,

15、 etc).1.2.4Broken, cracked or splintered fiberglass poles:Broken, cracked or splintered fiberglass poles will be rated as a functional defect.1.2.5Elastic shock-cording on aluminum and fiberglass poles:Broken or frayed elastic shock-cord will be rated as a functional defect.Exposed inner core of elastic shock-cording will also be rated as a functional defect.There will be a knot on the end sufficient to keep the shock-cord from passing through the I.D. of the tent pole when fully assembled.1.2.