Move cameral Brightness1. 固定Light adjuster(KM1-M8806-0XX;or KM1-M8806-110),将灰色面向上2. 调整Light,使vision清晰可见Unit→Axis→Light3. Utilities→Move camera→Brightness 进行各项设置4. 执行Black level.用黑色物将镜头遮住,按Black level键5. 按Execute键调整VR1---VR5l Scale1. Warn up 30mint2. 将Glass Board固定在Stage的正确位置Unit→Conveyor width:170→Locate pin→Push up→Edge clamp3. 认识MarkMark→选择NO.1 mark→Mark adjust→Head move→将mark移到屏幕中心附近→Find best→OK4. Utilities→Move camera→Scale 进行各项设置5. Execute→Save Multi cameral Brightness1. Utilities→Multi camera→Brightness 进行各项设置。

2. Pick up Light adjuster(KM1-M8806-0XX;or KM1-M8806-110)3. Execute→Savel Scale1. Warn up 30mint2. Machine→Option setting→Adjust mode2→Save and Exit3. Choose boardSet up→Board→MCH-SETUP4. Part Find best最好做一下)5. Utilities→Multi camera→Brightness 进行各项设置6. Pick up KMO-M880A-2027. Execute→Savel R轴精度补正1. Warn up 30mint2. Machine→Option setting→Adjust mode2→Save and Exit3. Choose boardSet up→Board→MCH-SETUP4. Utilities→Multi camera→R轴精度补正进行各项设置5. Pick up KMO-M880A-2026. Execute→Save Single cameral Brightness1. Utilities→Single camera→Brightness 进行各项设置。

2. Pick up Light adjuster(KM1-M8806-0XX;or KM1-M8806-110)3. Execute→Savel Scale1. Warn up 30mint2. Machine→Option setting→Adjust mode2→Save and Exit3. Choose boardSet up→Board→MCH-SETUP4. Part Find best最好做一下)5. Utilities→Single camera→Brightness 进行各项设置6. Pick up KMO-M880A-2027. Execute→Savel R轴精度补正1. Warn up 30mint2. Machine→Option setting→Adjust mode2→Save and Exit3. Choose boardSet up→Board→MCH-SETUP4. Utilities→Single camera→R轴精度补正进行各项设置5. Pick up KMO-M880A-2026. Execute→SaveFAMF1. Warn up 30mint。

2. Machine设定的变更Machine→Setting/Machine Information/Option setting/Vision/Adjust mode→Adjust mode23. Machine→Setting/Machine Information/Option setting/Conveyor/Conveyor Spec→Demo Fixed(也可以不执行)4. Mount mode的变更Machine→Setting/Machine Information/Installation Setting/Software/Mount Info. mode→V3.0 Extended5. Set up→SW Version→Password→Close6. Monitor→FAMF 按FAMF and Cycle Stop7. Board的选择Set up→Board→FAMF-71-A-OLD→Select 将Nozzle change 71 Type8. 调整camera的变更确认Monitor→FAMF 进行各项设定(table,main camera,adjust camera,main nozzle,adjust nozzle,measuring tool,std.upper XY等)。

9. Mount的变更确认Parts→choose NO.1 part→feeder set10. Board→Offset 设定BlockBoard→Mount 确认各项信息11. Parts 确认mount point将粘有两面胶的glass board固定于stage12. Parts AdjustParts→Adjust→Pick up→Test→Find best→Dump→OK13. Mark AdjustMark→Mark Adjust→Move head→(Test)→Find best→OK14. 自动运转Monitor→FAMF→Init→START→观察2Measure画面15. Result→Result1 确认IndexFeedback→Save→Init→START→Result→Result1 确认Index)→Init16. Set up→SW Version→Close。