电力专业英语4--继电保护2

上传人:宝路 文档编号:50651337 上传时间:2018-08-09 格式:PPT 页数:15 大小:184.63KB
返回 下载 相关 举报
电力专业英语4--继电保护2_第1页
第1页 / 共15页
电力专业英语4--继电保护2_第2页
第2页 / 共15页
电力专业英语4--继电保护2_第3页
第3页 / 共15页
电力专业英语4--继电保护2_第4页
第4页 / 共15页
电力专业英语4--继电保护2_第5页
第5页 / 共15页
点击查看更多>>
资源描述

《电力专业英语4--继电保护2》由会员分享,可在线阅读,更多相关《电力专业英语4--继电保护2(15页珍藏版)》请在金锄头文库上搜索。

1、电力专业英语电力专业英语4 4- - 继电保护继电保护2 2电气工程学院Date1继电保护继电保护2 2 Distance Relay 距离保护 Undervoltage Relay 低电压保护 Overvoltage Relay过电压保护 Blocking Relay闭锁继电器 Phase Angle or Out of Step Relay失步保护 Frequency Relay频率继电器 Directional Power Relay方向功率继电器 Instantaneous Overcurrent Relay瞬时过流保护 Differential Relay差动保护Date2Groun

2、ding System Formerly, many power systems were ungrounded systems using delta-delta transformers. Ungrounded systems suffer form several problems, including transient overvoltages that necessitate the use of two surge arresters for a single-phase transformer (one on each side of the winding), and tro

3、uble with rapid, automatic clearing of the very common phase to ground short circuit. 以前,许多电力系统采用角型接线变压器,为不接地系统 。不接地系统会带来很多严重的问题,包括暂态过电压, 因此,即使是单相变压器,也需要分别在原边和副边绕组 各安装一个避雷器。而且对于非常常见的相接地故障的快 速自动切除非常困难。Date3 An ungrounded system is connected to ground only by stray capacitances, so a single phase to g

4、round short circuit draws very little fault current. 不接地系统通过隔离电容接地,因此单相接地故障会产生 非常小的故障电流 To allow rapid detection and automatic clearing of ground faults, and to reduce insulation and arrester costs, grounded systems have become more common than ungrounded ones. 为了快速检测和清除接地故障,并且降低投资在隔离设备 和避雷器上的费用,接地系

5、统的应用越来越广泛。Date4 In many cases, the power transformers in a grounded system are connected delta wye, with the wye neutral grounded to the substation ground mat. 很多情况下,接地系统中的电力变压器的连接方 式为三角星型接线,星型接线的中性点和变电站 的接地网相连。 Generators and step-down transformers serving only three-phase loads are often grounded

6、through a resistance to limit the ground fault current to low values. 发电机和只带三相负荷的降压变压器一般通过电 阻接地,以降低接地故障电流的大小。Date5 Generator step-up transformers and step-down transformers serving four-wire distribution system are usually connected delta on the primary and wye on the secondary. Remember primary mea

7、ns input and second means output, so a step-up transformer primary is the low-voltage side but a step-down transformer primary is the high-voltage side. 发电机 升压变压器和向四线配电系统供电的降压变压器通 常在原边侧为三角型连接,在副边侧位星型链接。需要注 意的是原边指输入,副边指输出,因此升压变压器的原边 为低压侧,但降压变压器的原边为高压侧。Date6 Distribution transformers on four-wire syst

8、ems are connected phase to neutral (single phase) or wye (three phase) on the primary side. The secondary side of three-phase distribution transformers may be connected in either wye or delta. 四线系统的配电变压器的原边连接在相和中线上 (单相变压器)或连接成星型(三相变压器)。 三相配电变压器的副边可以星型或三角型连接。Date7 The wye-wye distribution transformer

9、 is used for four -wire (three phase conductors and a neutral conductor) systems, and the wye-delta distribution transformer is usually connected with the bank neutral not connected to ground. 星星连接配电变压器用于四线系统(三相导线和 中线),星角接线配电变压器的中性点通常不接 地。Date8 If the neutral is grounded, the bank tries to ground th

10、e feeder, and when ground faults occur on the primary side, the distribution banks will supply ground current. This usually causes a large number of blown fuses on wye-delta distribution transformers with grounded neutrals. 如果中性点接地,.,当在原边侧发生接地故障 时,配电变压器组中有接地电流流过。这会导致 星型中性点接地接线的配电变压器的保险熔断。Date9 Float

11、ing the bank neutral alleviates the problem, but may cause overvoltage problems such as ferroresonance. Wye-wye banks avoid the ferroresonance problem since they invariably have grounded neutrals on both sides. 变压器中性点浮地能减轻这一问题,但可能造成 过电压问题,例如铁磁共振。星星连接变压器组 不会产生铁磁共振问题,因为在原边和副边中性 点均接地。Date10 Instrument

12、transformers 仪用(或测量用)互感器 Instrument transformers are the input transducer for protective relays, but also metering (both fro revenue metering and for data acquisition). The two main types of instrument transformers are current transformers (CTs) and potential transformers (PTs). The latter are also

13、called voltage transformers (VTs), with no difference intended. 测量用互感器指的是保护继电器的输入传感器,也指计量 仪表(例如电费计量和数据采集)的输入传感器。两种主 要的测量用互感器为电流互感器(CT)和电压互感器( PT),后者也简称VT。Date11 The CT acts to step the current down, say from 1000A on the primary to 5A on the secondary. This would give a CT ratio of 1000:5A or 200:1A

14、, and would require 200 turns on the secondary (assuming one primary “turn”). CT的作用是降低电流,例如将原边1000A的电流 降至副边的5A。则CT的变比为1000:5A 或200:1A ,副边绕组的匝数为200(假设原边绕组匝数为1 )Date12 Current transformer secondaries are typically rated at 5 A, although some are rated at 1 A. This is the continuous rating, and it may

15、be exceeded by a factor of 10 or 20 for a short time, especially during a short circuit in supplying relays that provide overcurrent protection. 电流互感器二次侧典型额定电流为5A,有时为 1A.这只是额定标称值,其二次侧允许短时过电流 10-20倍,尤其是作为过流保护的输入传感器,有 短路电流流过时。Date13 Current transformers for relaying purposes are given accuracy class r

16、atings, such as C400 or T400 (sometimes written as 10C400 or 10T400). The letter C indicates that its performance may be calculated from its magnetization curve. The letter T indicates that its performance must be determined by test. 保护用电流互感器均给出其(测量)精度等级, 例如C400或T400(有些标为10C400或10T400)。 字母C表示其特性通过其磁化曲线计算出来。字 母T 表示其特性由实验决定。Date14 The number following the letter C or T is t

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 中学教育 > 教学课件

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号