冷凝压力调节阀英文说明书

上传人:ji****n 文档编号:47707817 上传时间:2018-07-04 格式:PDF 页数:3 大小:252.88KB
返回 下载 相关 举报
冷凝压力调节阀英文说明书_第1页
第1页 / 共3页
冷凝压力调节阀英文说明书_第2页
第2页 / 共3页
冷凝压力调节阀英文说明书_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

《冷凝压力调节阀英文说明书》由会员分享,可在线阅读,更多相关《冷凝压力调节阀英文说明书(3页珍藏版)》请在金锄头文库上搜索。

1、 Condensing pressure control valve Condensing pressure control valve PRV series PRV series shanghai kaobo machinery electrical equipment co., ltd http:/www.sh- samanthash- Product description PRV series condensing pressure control valves are normally installed on the coolant pipe of a condenser (usu

2、ally on the entrance). Because the PVR series can adjust the flow rate of the coolant by sensing the refrigeration recycling pressure according to changes in condenser pressure, the result is a significant improvement in coolant use efficiency. In this manner, PRV series vales are able to provide on

3、 demand cooling. When condenser pressure is raised in the compressor, the valves will be opened automatically so that there is more coolant moved into the condenser to quicken the refrigeration cooling process. Alternately, coolant levels will become lower with the pressure falling and valves being

4、closed automatically, therefore the condensing pressure is kept within a normal operating range. PRV series valves adjusting method: The adjusting lever can be rotated when regulating, the controlling pressure raises by rotating clockwise, alternately by rotating counter clockwise the pressure drops

5、. Type parameter Kv value indicates the flow rate when the medium pressure through valve is 1bar , unit=m3/h,density =1000kg/m3 Type Condenser Liquid Opening pressure (MPa)Kv m3/h Refrigerant Adjusting range (MPa) Max. working pressure (MPa) Max. test pressure (MPa) MediumMax. working pressure (MPa)

6、 Max. () Low pressure PRV-010G R134a R22 R407C R404A/507 0.5-1.8 4.2 52 Water 1 60 0.75 0.8 PRV-015G 2.5 PRV-020G 3.2 PRV-025G 5.0 PRV-032G 7.1 PRV-040G 9 PRV-050G 11.8 PRV-065G 13.5 High pressure PRV-010G R410A 0.7-2.5 4.8 6.0 2.4 0.8 PRV-015G 2.5 PRV-020G 3.2 PRV-025G 5.0 PRV-032G 1.5-2.9 7.1 PRV-

7、040G 9 PRV-050G 11.8 PRV-065G 13.52 Condensing pressure control valve Condensing pressure control valve PRV series PRV series shanghai kaobo machinery electrical equipment co., ltd http:/www.sh- samanthash- Dimension Installation 1、The capillary tube can be connected to the top of the condenser when

8、 installing, the entry port to the corresponding cooling pipe, exit port to the coolant entry port of the condenser. 2、The pressure is set to 7.5 bar by factory, users can adjust it properly. You can rotate the adjusting lever when regulating, the controlling pressure raises by rotating clockwise, a

9、lternately by rotating counter clockwise the pressure drops. Overall dimension Type Condenser port Liquid port Dimension (mm) Length (L) Height (H)PRV-010 6mm(1/4in) bell mouth 3/8 100 170 PRV-015G 6mm(1/4in) bell mouth G1/2 84 204 PRV-020G 6mm(1/4in) bell mouth G3/4 84 204 PRV-025G 6mm(1/4in) bell

10、mouth G1 100 220 PRV-032G 6mm(1/4in) bell mouth G1-1/4 110 230 PRV-040G 6mm(1/4in) bell mouth G1-1/2 110 230 PRV-050G 6mm(1/4in) bell mouth G2 120 250 PRV-065G 6mm(1/4in) bell mouth G2-1/2 125 265 PRV-080G 6mm(1/4in) bell mouth G3 130 270 Condensing pressure control valve Condensing pressure control

11、 valve PRV series PRV series shanghai kaobo machinery electrical equipment co., ltd http:/www.sh- samanthash- Additional parts Picture 1 Picture 2 Type T001 T013 Z Details ZTG Copper tube T001 Picture 1: One end is 7/16, one end is pin valve T002 Picture 2: Both ends are 7/16 T Copper tube 01 One meter 02 Two meters 05 Five meters 3 3 5 5 6 6 Z Pin valve connecting C Bell mouth connecting Size (inch) Pipe diameter (mm) 1/4 6 3/8 10 1/2 13 5/8 16 3/4 19 7/8 22 1 25

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 医学/心理学 > 基础医学

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号