莱姆电流传感器at10b5

上传人:ji****n 文档编号:47052082 上传时间:2018-06-29 格式:PDF 页数:3 大小:737.41KB
返回 下载 相关 举报
莱姆电流传感器at10b5_第1页
第1页 / 共3页
莱姆电流传感器at10b5_第2页
第2页 / 共3页
莱姆电流传感器at10b5_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

《莱姆电流传感器at10b5》由会员分享,可在线阅读,更多相关《莱姆电流传感器at10b5(3页珍藏版)》请在金锄头文库上搜索。

1、090609/6LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior Page 1/3 IPN = 5 . 150 AFeaturesRMS (average) output 0-5V DC voltage output Split-core type 16 mm sensing aperture for non-contact measurement Terminal output Isolated plastic case r

2、ecognized according to UL 94-V0.AdvantagesHigh isolation between primary and secondary circuits Compact case Cost-effective solution Easy installation ApplicationsAutomation and Supervision Current measurement for process regulation by distributed PLCs or remote control (e.g. SCADA software) Safety

3、and Condition Monitoring Load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors)Application domainEnergy and Automation Electrical dataPrimary nominal current rmsOutput voltageType IPN (A.t.Rms)VOUT (V DC)50-5AT 5 B5 100-5AT 10 B5 200-5AT 20 B5 500-5A

4、T 50 B5 1000-5AT 100 B5 1500-5AT 150 B5R LLoad resistance 1MW VCSupply voltageself-powered VSZOutput clamping voltage7.5V POverload capability - continuous120% of IPN - 1 min150% of IPNPerformance dataXAccuracy IPN, TA = 25C (excluding offset) 2% of IPNLLinearity error 0.5% t rResponse time to 90% o

5、f IP step 300ms BWFrequency bandwidth50/60HzGeneral dataTAAmbient operating temperature- 20 . + 60C TSAmbient storage temperature- 20 . + 85C mMass90g IPxxProtection degreeIP40AC Current transducer AT-B5Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isola

6、tion between the primary circuit (power) and the secondary circuit (measurement). 0-5V DC voltage output proportional to the RMS value of the primary current.IPN = 5 . 150 AFeaturesRMS (average) output0-5V DC voltage output Split-core type 16 mm sensing aperture for non- contact measurementTerminal

7、output Isolated plastic case recognizedaccording to UL 94-V0.Advantages High isolation between primary and secondary circuits Compact case Cost-effective solution Easy installationApplicationsAutomation and SupervisionCurrent measurement for process regulation by distributed PLCs orremote control (e

8、.g. SCADA software)Safety and Condition Monitoring Load monitoring for protectionsystems and predictive maintenance (e.g. conveyers,pumps or HVAC motors)Application domain Energy and AutomationAC Current transducer AT-B5Split-core transducer for the electronic measurement of AC waveform currents, wi

9、th galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). 0-5V DC voltage output proportional to the RMS value of the primary current.Electrical dataPrimary nominal Output voltage Typecurrent rmsIPN (A.t.Rms) VOUT (V DC)5 0-5 AT 5 B5 10 0-5 AT 10 B5 20 0-5 AT

10、 20 B5 50 0-5 AT 50 B5 100 0-5 AT 100 B5 150 0-5 AT 150 B5RL Load resistance 1 MW VC Supply voltage self-powered VSZ Output clamping voltage 7.5 V P Overload capability - continuous 120 % of IPN- 1 min 150 % of IPNPerformance dataX Accuracy IPN, TA = 25C (excluding offset) 1.5 % of IPNeL Linearity e

11、rror 0.5 % of IPN tr Response time to 90% of IPN step 300 ms BW Frequency bandwidth 50/60 HzGeneral dataTA Ambient operating temperature - 20 . + 60 C TS Ambient storage temperature - 20 . + 85 C m Mass 90 g IPxx Protection degree IP40090609/6LEM reserves the right to carry out modifications on its

12、transducers, in order to improve them, without prior Page 2/3 Current Transducer AT-B5Isolation characteristicsVb Rated isolation voltage rms 1) 300 Vwith IEC 61010-1 standards and following conditions:- Reinforced isolation- Over voltage category CAT III- Pollution degree PD2- Heterogeneous field V

13、d Rms voltage for AC isolation test 2), 50Hz, 1min. 3.5 kV dCp Creepage distance 6 mm dCl Clearance distance 6 mm CTI Comparative tracking index (Group I) 600Notes: 1) If insulated cable is used for the primary circuit, the isolation voltage category can be improved according to the primary cable in

14、sulation category (please refer to the cable manufacturers indications) 2) between primary (completely filling the hole) and secondary.Safety and warning notesIn order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these ins

15、tructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under .Caution! R

16、isk of dangerIgnoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have rceived an appropriate training. The corresponding national regulations shall be observed during installatio

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 生活休闲 > 社会民生

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号