1、 目录目录 Chapter 1 Product Introduction . 1 1.1 Product Specification . 1 1.2 Nameplate Introduction . 1 1.3 Models . 2 Chapter 2 Installation Instructions . 3 2.1 Exterior Overview and Mounting Dimensions . 3 2.1.1 Product Exterior Overview . 3 2.1.2 Mounting Dimensions . 3 2.2 Mechanical Installation

2、 Instructions . 3 2.2.1 Interval for Installing . 3 2.2.2 Uninstall Instruction . 4 2.3 Standard Wiring . 4 2.3.1 VD100 Wiring Diagram. 4 2.3.2 Major Loop Terminal Wiring . 4 2.3.3 Control Terminal Wiring . 6 Chapter 3 Keyboard Operation Procedure . 7 3.1 Operation Panel . 7 3.1.1 Function Specifica

3、tion of Keys . 7 3.1.2 Display Of LED Signal Light and Digital Tube . 8 Chapter 4 Function Parameters . 9 4.1 Parameter Table . 9 4.2 Parameter Initialization . 21 Chapter 5 Monitoring Mode Introduction . 22 Chapter 6 Faults Detection and Troubleshooting . 23 6.1 Faults Detection and Troubleshooting

4、. 23 6.2 Alarm Record Query . 25 6.3 Alarm Record Initialization . 25 1 Chapter 1 Product Introduction 1.1 Product Specification Input/output features Input voltage range: 380/220V15% Input frequency range: 4763Hz Output voltage rang: 0rated input voltage Output frequency range: 0630Hz Peripheral in

5、terface features Programmable digital input: 5 switch signal inputs Programmable analog input: AI: 010V or 020mA input Relay output: 1 way output Analog output: 1 way output, 010VTechnical function features Control mode: V/F control Overload capacity: 150% rated current 60s; 180% rated current 10s;

6、200% rated current 1s Speed ratio: 1:50 Carrier frequency: 2.016.0 kHz Performance features Frequency setting mode: digital setting, analog setting, serial communication setting, multi-velocity and simple PLC setting. Settings can be combined and modes can be switched. PID control function Simple PL

7、C and multi-velocity control function: 16-gear velocity control Swing frequency control function Time control function Frequency agility function S curve function QUICK/JOG function: users can customize function with this multi-function key Automatic voltage adjustment function: maintain steady voltage output automatically when the grid voltage alters. Provide with multiple fault protection function in circumstances like overcurrent, overvoltage, undervoltage, overtemperature, phase loss and overload. 1.2 Nameplate Introduct