《QCT424-99标准(英文版)》由会员分享,可在线阅读,更多相关《QCT424-99标准(英文版)(5页珍藏版)》请在金锄头文库上搜索。
1、Introduction to the Change of Standard CodeAccording to the requirement of ZJJJBH 1998 No. 216 document of China State Bureau of Quality &Technical Supervision as well as GJG 1999 No. 126 reply of State Bureau of Machine Building Industry, the original standard code ZB T36 010-89 is changed as the i
2、ndustrial standard code QC/T 424-1999, with the content keeping the same temporarily. Please use the new standard code in reference.Specialized Standard of PRCTest Methods for Electrical Characteristic of Automobile Alternator ZB T36 010-891 Subject Content and Applicable Scope This standard defines
3、 the test methods and general requirement for the electrical characteristics of automobile alternator (referred to as “generator” for short hereinafter). This standard applies to automobile alternator (whose cooling method is specified by the generator manufactory). 2Terms and Code2.1Test Voltage Ut
4、 (V)It is the specified voltage value when testing the output current. 2.2Cut-in Speed nA (r/min)It refers to the generator speed when the generator begins to output current for the first time; this speed depends on the pre-excitation power (input), speed change rate, battery voltage and residual fl
5、ux density in rotor. 2.3Zero-amp Speed no (r/min)It is the speed when the generator voltage has reached the specified test voltage Ut but there is no current output. (In the current-speed characteristic curve I=f (n), the point meets the x-coordinate.2.4Minimum Application Speed nL (r/min)The standa
6、rd specifies this speed is 1,500r/min, which equals to the generator speed when the engine is at idle speed.2.5Rated Speed nR (r/min)It is the speed when the generator outputs rated current IR. The speed is specified by the product standard. 2.6Minimum Application Current IL (A)It is the current out
7、put of generator under the test voltage Ut and with the speed nL=1,500r/min.2.7Rated Current IR (A) It is the minimum current output of the generator under the test voltage Ut and with the rated speed nR (the rated current value is specified by the generator manufactory, and shall be marked on the n
8、ameplate of generator).2.8Maximum Current Imax (A)It is the current output of generator under the test voltage Ut and with the maximum continuous speed nmax (the speed is specified by the generator manufactory). 3Electrical Characteristic Test3.1Current-Speed Characteristic3.1.1ObjectiveThe test is
9、to obtain the relation between current and speed when the generator voltage remains at the test voltage Ut. 3.1.2Circuit and Requirement 3.1.2.1The circuit is shown in Figure 1 Approved by China Automobile Industry Union on March 10, 19891989-07-01ZB T36 010-89Outward excitation is possibleIntegral
10、alternator or alternator with external regulatorCharge indicatorBatteryVoltmeterAmmeter Figure 1In the figure, R is a rheostat selected according to alternator.a.The voltmeter shall be directly connected to the output terminal of the generator.b.The applied lead wire shall conform to the following r
11、equirements: the resistance between the generator output terminal and battery “+” pole terminal shall not exceed 0.007; the resistance between the generator housing and battery “-” pole terminal shall not be more than 0.003; as the external regulator is adopted, the resistance between the grounding
12、terminal of generator and generator housing shall not exceed 0.003, the total resistance of the remaining wire of regulator shall not exceed 0.005.3.1.2.2RequirementThe current-speed characteristics shall include the following five points.a.Cut-in Speed nAIncrease the generator speed gradually until
13、 the charge indicator indicates the charge begins, and then note down the speed.The rated value of the charge indicator will influence the cut-in speed. The rated value shall be 2W unless there is special requirement. b.Zero-amp Speed no (indirect measurement)Reduce the generator speed until the out
14、put current is between 5% of rated current and 2A, but no less than 2A, and note down the speed and current for the purpose of illustrated zero-amp speed. Extend the current-speed characteristic curve to meet the x-coordinate, and the speed of this meeting point is the zero-amp speed. The graphicall
15、y epitaxial method shall be carried out after finishing the test items. c.Minimum Application Current ILAdjust the generator speed until nL=1,500r/min, and note down the output current. d.Rated Current IRAdjust the generator speed to the rated speed, and note down the output current.e.Maximum Curren
16、t ImaxAdjust the generator speed to the maximum speed nmax specified by the generator manufactory, and note down the output current.3.1.3Test Conditionsa.The test shall be carried out at the room temperature of 235C, and the temperature deviation shall be noted down; the recorded temperature shall be the temperature before air