ABB传动调试软件DriveWindow介绍

上传人:汽*** 文档编号:576455552 上传时间:2024-08-20 格式:PPT 页数:23 大小:1.69MB
返回 下载 相关 举报
ABB传动调试软件DriveWindow介绍_第1页
第1页 / 共23页
ABB传动调试软件DriveWindow介绍_第2页
第2页 / 共23页
ABB传动调试软件DriveWindow介绍_第3页
第3页 / 共23页
ABB传动调试软件DriveWindow介绍_第4页
第4页 / 共23页
ABB传动调试软件DriveWindow介绍_第5页
第5页 / 共23页
点击查看更多>>
资源描述

《ABB传动调试软件DriveWindow介绍》由会员分享,可在线阅读,更多相关《ABB传动调试软件DriveWindow介绍(23页珍藏版)》请在金锄头文库上搜索。

1、ABBABB传动调试软件传动调试软件DriveWindowDriveWindow介绍介绍 ABB Oy FINLAND- 2 -DriveWindow 2DriveWare IntroductionDriveWindow is Windows Application for commissioning and maintaining ACS600, ACS800, ACS6000, ACS1000 and DCS600. Operating system Windows NT, Windows 2000, or Windows XPFunctionsControl operations (st

2、art, stop, references, etc.)Monitoring signals in numerical and graphical formatParameters (changing values)Datalogger (controls, display)Fault Logger (display faults, controls)Back-up & Restore (complete software back-up)All functions over network (control, monitoring, etc.)Required DriveWindow har

3、dware:ISA card, orPCMCIA-card (PCMCIA-slot or PCI-slot with PCI/PCMCIA adapter)Network adapter when using remote connectionDDCS cabling ABB Oy FINLAND- 3 -DriveWindow 2DriveWare Connection.8 7 6 0NDBU-95/85NISA-03 (ISA)DDCS-protocol 1 Mbit/sORGOFmax 1000m(NOCR-01 isrequired)HCSmax 200 mORPOFmax 30m.

4、GOF= Glass Optic FibreHCS = Hard Clad Silica FibrePOF = Plastic Optical FibreConnection alternatives:1. Direct connection (point-to point) between the PC and the drive (the most common manner)2. Through the distributor, DriveWindow-link (sectional drives). An individual address to be set by paramete

5、r 70.02 or 70.15 for every drive in the link.3. Ring. Drives can be connected in a ring .An individual address to be set by parameter 70.02 or 70.15 for every drive in the link.Note! all the drives in the ring should have power supply on all the time. Otherwise the ring will break.Note ! Do not use

6、address one (1) if several drives are in a network (ring or connected together with the distributors). The first (1.) address are meant for sparepart use.2.CH 3CH 3CH 3Optical distributor 9 channelsCH 3NDPA-02 (PCMCIA)+ NDPC-02 (5Mb) or NDPC-12 (10Mb)MSTR8 7 6 0NDBU-95/85MSTRCH 31.3.CH 3PCMCIA-adapt

7、er (PCI)+ NDPA-02 (PCMCIA)+ NDPC-02 (5Mb) or NDPC-12 (10Mb)ORHCSmax 200 mORPOFmax 30m ABB Oy FINLAND- 4 -DriveWindow 2DriveWare ORDouble-clickthe program iconGetting start1.Select OKMost of the operationscan be done only when the drive is in REMOTE-control(Not the local control with the DriveWindow)

8、2.1. ABB Oy FINLAND- 5 -DriveWindow 2DriveWare User InterfaceTitle barDriveWindow areaMenu barTool barStatus barOFF-LINE or COMM. BREAKNOT RUNNINGRUNNING (forward)FAULTWARNINGDRIVE STATUSBROWSE TREEPANETREND DISPLAY PANETREND SETTINGSPANEITEM LIST PANESize of the window partscan be changesOpen Brows

9、e Tree by Double-clicking the motor ABB Oy FINLAND- 6 -DriveWindow 2DriveWare ToolbarStatus refresh off/onSTANDARD (general)MONITORLOGGERCutCopyDeleteZoom InZoom OutReset ZoomAdd ItemLock/unlock Item into theDesktopUpdate itemsSelect On-/off-line for itemsChange valueAdd/removeMonitor ItemsStartMoni

10、toringStopMonitoringPauseMonitoringClearMonitorStopDataloggerTrigDataloggerClearDriveDataloggerClearDataloggerGraphStartDataloggerUpload DataloggerAdd/RemoveLoggerItems ABB Oy FINLAND- 7 -DriveWindow 2DriveWare Step buttonSet reference (Enter)Reference value (DW 2.1)Drive Panel ToolbarReference edit

11、 fieldStopStartResetCoast stopDirection of rotationClear faultloggerTake/Release Control(Local/Remote)Name and address of the selected drive ABB Oy FINLAND- 8 -DriveWindow 2DriveWare Setting of parametersClick + symbol by mouseDouble-click group by mouseDouble-click item by mouse+Select or type new

12、value for the parameter.Select OK1234NOTE!If the drive running when a parameter group is expanded (opened into the Item List Pane), editing of the some parameters are not possible. This READ ONLY-status remains afterward even the drive have been stopped. Solution:1. Disconnect Server-command from th

13、e Network-menu2. Network Servers -command from the Network-menu ABB Oy FINLAND- 9 -DriveWindow 2DriveWare Actual values2Click + symbol with mouseClick the group with mouseClick item with mouse+Select ACTIVATE/DEACTIVATE ITEMSfrom the Toolbar4513NOTE! If desired values are located in a different grou

14、psuse LOCK/UNLOCK from the Toolbar to keep them in the Item List Pane ABB Oy FINLAND- 10 -DriveWindow 2DriveWare Graph preferencesLine display typeUnscaled cursor valuesScaling method.Change scalings by double-clicking a row. Scale setting depend on selelected Scaling Method. Values at 100 and 0Coef

15、ficient and Offset(display= coeff *Act. + offset)123 ABB Oy FINLAND- 11 -DriveWindow 2DriveWare Selected item can be removed from the Monitor by the DEL-key of the keyboard or -button from the ToolbarMonitor: Select itemsClick item by mouse1Select ADD/REMOVE MONITORED ITEMSfrom Toolbar2Selected item

16、 shown in the monitor and it is markedin the signal list3 ABB Oy FINLAND- 12 -DriveWindow 2DriveWare Monitor: Settings and scalingScalings; depend on selected Scaling Method, see previous slide.Display = Cofficient*ACT value + offset ORDisplay = 100 % with full signal rangeSize of the buffer in seco

17、nds “Size of the history behind the screen”Sampling interval in ms “Size of the history”Monitor mode:Normal or Fast Within the Normal mode min. sampling interval is 10mswithin Fast-mode it is 1msSet y-axis minimum and y-axis maximum =You can set at any time.=You can set only when monitoring is clear

18、ed. =You can set when monitoring is stopped or paused Length of the screen in seconds Change the length by double-click it, if it is necessary ABB Oy FINLAND- 13 -DriveWindow 2DriveWare Monitor: Operating1.Add/remove monitored items2.Start or continue monitoring3.Stop monitoring4.Pause monitoring5.C

19、lear monitor1Select STARTSelect STOP or PAUSEPrint outExport data in numerical form e.g. into the Excel-programCopy Graph into the Clipboard23Open a saved graph file in the offline modeSave the graphs to the fileGraph file commentGraph Preferences: scaling method ,how graphs are shown etc. ABB Oy FI

20、NLAND- 14 -DriveWindow 2DriveWare WorkspaceChange the preferences for workspace save & restoreDriveWindowWorkspaceOpen a saved workspace file in the online or offline modeSave the workspace to the file ABB Oy FINLAND- 15 -DriveWindow 2DriveWare Fault logger4It is possible clear the selected driveFAU

21、LT LOGGEROFF-LINE or COMM. BREAKNOT RUNNINGRUNNING (forward)FAULTWARNINGDRIVE STATUSSelect the row(s) and update items Click theFault Logger1Fault or Warning messages32Desktop preferences:From Cache: values are pick up from the OPC Server cacheFrom Device= “all actual values are pick up from the dri

22、ve with separate commands”.It is not on-line and causes less load for the communication than other selections. Thus the contents of the fault logger are not updated even it is open on the desktop. By double-clicking with mouse the fault logger icon or by the Update Items-button the contents will be

23、updated.PUT ON-LINE= is full time and real on-line connection. This is applicable also with the parameters and signals.But this causes more load for the communication, which should take into consideration in case by case. See more information from DriveWindow ONLINE HELP ABB Oy FINLAND- 16 -DriveWin

24、dow 2DriveWare Save parameter file to the PC1Select the driveGive a filename and locate the file into a hard disk/directory234Give a comment and select OKCommand is disabled (grayed) while the LOCAL CONTROL. Use Take/Release ControlNOTE!If the drive running when a parameter set is save to the PC, ed

25、iting of the some parameters are not possible in the OFFLINE. This READ ONLY-status remains in the parameter file. For the backup purpose create always the FULL BACKUP of the control board or control unit (NAMC-xx, RMIO-xx, NDCU-xx), see slide 18. ABB Oy FINLAND- 17 -DriveWindow 2DriveWare Download

26、parameters into the drive14567Open the fileSelect the drive(Remote Control)Select DOWNLOADDifferent sw-versionsSw conflict!Select type 10.98Set parameters into the group 99 manually afterwardsAre you sure?Pick up file235NOTE! In case of the ACS800, check after download the parameters from the group

27、83 and 84 (If Adaptive Program is in use) ABB Oy FINLAND- 18 -DriveWindow 2DriveWare Create full Backup of the motor control boardSelect Save As.Open the new “backup FOLDER” (The drive should be in REMOTE CONTROL= not the control from the DriveWindow)2BackupSelect the drive5Give a filename6134Last a

28、ction: Close your folderFILE-menu-SYSTEM SOFTWARE- CLOSE7 ABB Oy FINLAND- 19 -DriveWindow 2DriveWare Note! For safety reasons you cannot restore any drivewhile control of some drive is taken with DW=LOCAL control.The command in the menu is disabled (grayed).Restore Backup file into the motor control

29、 board2Are you sure?Open the backup fileSelect the System Software / Restore5Select the drive where you want RESTORE (=backup file) 3Select the right BACKUP (-file) for the RESTORE (The backup foldermay contain more than backup). 41Dont do any operations with drive or PC during Restoring6 ABB Oy FIN

30、LAND- 20 -DriveWindow 2DriveWare DATALOGGER: Overview-Datalogger is data recorder. Its locating in the drive and control of it are done by the DriveWindow-Number of dataloggers are two (2) (with the NAMC-03/-11 in ACS 600 one (1) datalogger is available)-Total number of samples (n) are 1024 (ACS 600

31、, ACS 800)-Number of the channels are four (4) (ACS 600, ACS 800)-If four (4) channels were defined, samples per channel are 256-Triggering conditions are defined by user (fault, level of a measured signal,warning etc.)Channel 1Value 1Value 2Value 3Value 4Value ne.g.ActualSpeedChannel 2Value 1Value

32、2Value 3Value 4Value ne.g.ActualFreq.Channel 3Value 1Value 2Value 3Value 4Value ne.g.ActualCurrentChannel 4Value 1Value 2Value 3Value 4Value ne.g.ActualTorquenLOCATION OF THE DATALOGGERCONTROL OF THE DATALOGGERDriveWindow ABB Oy FINLAND- 21 -DriveWindow 2DriveWare You can set x-axis length of the mo

33、nitor or a datalogger at any time. X-axis length of a datalogger can also change automatically when the datalogger is uploaded. Note! If a datalogger has never been uploaded, DriveWindow does not know for sure the size of a datalogger channel buffer. Thus DriveWindow does not do any checking about t

34、he x-axis length, until it knows more about the datalogger. When size of the datalogger channel buffer is known, DriveWindow does not accept improper setting of x-axis length.Interval, where you can change the logging interval of the current datalogger.Pre-Trig (ms), where you can change the number

35、of values kept in the current datalogger before the triggering event. The value is given and shown as time, but the datalogger actually uses a count.Trig Hysteresis, where you can change the triggering level hysteresis, which is used in triggering the current datalogger.Trig Level, where you can cha

36、nge the triggering level, which is used in triggering the current datalogger.Trig Conditions (fault, warning, level etc).Trig Variable, where you can change OPC address of the variable, which is used in triggering the current datalogger.Status shows the state of the datalogger. Double-clicking toggl

37、es it on-line/off-line. Trigged By shows the triggering reasonScale channel 1; Two scaling methods available. Same method selected for Monitoring and Datalogger from FILE-menu:Graph/Preferences. Change the scale by double-click channel number.DATALOGGER: Settings ABB Oy FINLAND- 22 -DriveWindow 2Dri

38、veWare Select the new signal by the mouse Add the signal into the datalogger. Repeat points 2 and 3 with all four channels. Note! You cannot specify used channel. DriveWindow defined used channel automatically 345Start datalogger6When FILLED, upload data27DATALOGGER: Example1Delete existing signals from Datalogger one by one Make your datalogger settings.Scalings, like X-axis length can be done after the uploading8

展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 高等教育 > 研究生课件

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号