1、Introductions of PLC and MCUA PLC is a device that was invented to replace the necessary sequential relay circuits for machine control. The PLC works by looking at its inputs and depending upon their state, turning on/off its outputs .The user enters a program, usually via software or programmer tha

2、t gives the desired results.PLC are used in many “real world” applications. If there is industry present, chances are good that there is a PLC present. If you are involved in machining, packaging, material handling, automated assembly or countless other industries, you are probably already using the

3、m. If you are not, you are wasting money and time. Almost any application that needs some type of electrical control has need for PLC.For example, lets assume that when a switch turns on we want to turn a solenoid on for 5 seconds and then turn it off regardless of how long the switch is on for. We

4、can do this with a simple external timer. What if the process also needed to count how many times the switch individually turned on? We need a lot of external counters.As you can see, the bigger the process the more of a need we have for a PLC. We can simply program the PLC to count its inputs and t

5、urn the solenoids on for the specified time.We will take a look at what is considered to be the “top 20” PLC instructions. It can be safely estimated that with a firm understanding of there instructions one can solve more than 80% of the applications in existence.Thats right, more than 80%! Of cours

6、e well learn more than just these instructions to help you solve almost ALL your potential PLC applications.The PLC mainly consists of a CPU, memory areas, and appropriate circuits to receive input/output data, as shown in Fig. 19.1 We can actually consider the PLC to be a box full of hundreds or th

7、ousands of separate relays, counters, timer and date storage locations. Do these counters, timers, etc. really exist? No, they dont “physically” exist but rather they are simulated and can be considered software counters, timers, etc. These internal relays are simulated through bit locations in regi

8、sters.What does each part do?INPUT RELAYS-(contacts) These are connected to the outside world. They physically exist and receive signals from switches, sensors, etc. Typically they are not relays but rather they are transistors.INTERNAL UTILITY RELAYS-(contacts) These do not receive signals from the

9、 outside world nor do they physically exist. They are simulated relays and are what enables a PLC to eliminate external relays. There are also some special relays that are dedicated to performing only one task. Some are always on while some are always off. Some are on only once during power-on and a

10、re typically user for initializing data what was stored.COUNTERS These again do not physically exist. They are simulated counters and they can be programmed to count pulses. Typically these counters can count up, down or both up and down. Since there are simulated, they are limited in their counting

11、 speed. Some manufacturers also include high-speed counters that are hardware based. We can think of these as physically existing. Most timers these counters can count up, down or up and down. TIMERS These also do not physically exist. They come in many varieties and increments. The most common type

12、 is an on-delay type. Other include off-delay and both retentive and non-retentive types. Increments vary from 1ms through 1s.OUTPUT RELAYS-(coil) These are connected to the outside world. They physically exist and send on/off signals to solenoids, lights, etc They can be transistors, relays, or tri

13、acs depending upon the model chosen.DATA STORAGE-Typically there are registers assigned to simply store data. There are usually used as temporary storage for math or data manipulation. They can also typically be user power-up they will still have the same contents as before power war removed. Very c

14、onvenient and necessary!A PLC works by continually scanning a program. We can think of this scan cycle as consisting of 3 important steps, as shown in Fig.19.2 There are typically more than 3 but we can focus on the important parts and not worry about the others. Typically the others are checking th

15、e system and updating the current and timer values.Step 1-CHECK INPUT STATUS-First the PLC takes a look at each input to determine if it is on or off. In other words, is the sensor connected to the first input on? How about the second input? How about the thirdIt records this data into its memory to

16、 be used during the next step.Step 2-EXECUTE PROGRAM-Next the PLC executes your program one instruction at a time. Maybe your program said that if the first input was on then it should turn on the first output. Since is already knows which inputs are on/off from the previous step, it will be able to decide whether the first output should be turned on based on the state of the first input. It will store the execution results for use later during t