1、HonegwelServer RoomsApplication Overview SeriesProtecting Server Rooms and Communications CentersProtection forComputers and Server RoomsDescription and PurposeHigh-speed communications and networking are a requirement in todays business environment. Modern commercial facilities include communicatio

2、n centers and computer server rooms. Rooms that house server equipment are environmentally controlled clean rooms requiring planning that extends beyond just security and access control. Vista 32, 128, and 250 series control panels can notify the IT Staff of trouble in the server room before a serve

3、r fails, saving thousands of dollars in employee wages.Using the Vista controller, you can: Monitor the condition of both occupied and unoccupied facilitiesMonitor Threshold Levels for temperature and humidity Monitor power and battery status of UPS systemSense and report power failures to the IT St

4、aff Sense water levels in drip pans for air conditioning ductwork. Notify IT administrators of network outages. Sense and report unauthorized intrusion into the server roomHelp your client to manage risks of server failures, Use the VISTA 128, and 250 series controls to supervise the status of the s

5、erver room.HighHumidityAccess ControlVideoSurveillanceWaterLeaks(3IntrusionDetectionFigure 1: Server Room SupervisionHighTemperaturePowerSupervisionNetworkPresenceUser BenefitsPreventing failures controls the cost Unplanned costs can soar when servers or communication equipment stop working while em

6、ployees are on the clock. For example, imagine the cost of 12 employees during a server failure of just two hours. If the average rate of pay was $20.00 per hour, a single two-hour outage would cost the business $480.00. How many server failures will a business tolerate each year? The system can min

7、imize a businesss exposure to unplanned costs related to server equipment failure.Additional security: The system keeps unwatched doors locked, and warns users if doors are left propped open. Propped doors invite privacy problems with sensitive documentation or other personal data. Minimize this thr

8、eat by keeping doors leading to sensitive data locked.Keep a video record: The system,s optional camera switcher can activate a camera each time the server room door is opened, when an alarm occurs, each time an unauthorized access occurs, and you can switch to a camera by simply pressing a button.

9、This allows for central monitoring of all activities in and around the server room.Helps to prevent unauthorized entry by employees or others into secure areas: The system minimizes employee traffic, allowing entry only into areas where authorized.Prevent unauthorized entry outside of desired time s

10、chedules: After hours, VistaKey can automatically reduce or increase a users authority into normal working areas based upon predetermined schedules assigned to the individual.Supervise the temperature: Computers and communications equipment generate a great deal of heat. Server rooms must be air con

11、ditioned to keep equipment from overheating. The system can supervise this important status.Watch over the humidity level: High humidity can be a danger to electronic equipment. Leaving a door propped open can allow warm, moist air to enter the server room, causing immediate condensation on circuit

12、boards and components. The system can warn you when the humidity is high, so you can adjust humidity levels as needed. The system can also automatically adjust levels in humidity when connected to switch on dehumidifiers and other air conditioning appliances.Detect and report power failures: Power f

13、ailures can disable computer equipment. The system can sense when power fails or when UPS battery trouble exists. This helps the IT Staff to keep backup power sources in working condition.Watch out for leaks and floods: Air conditioning ducts can condense moisture that drips. Drip pans capture the w

14、ater before it damages ceiling tiles or electronic components below. In the dusty environment above the ceiling tiles, drip pan drains becomeFigure 2: System Components for Server Roomsclogged through time, allowing drip pans to fill beyond capacity. The system can notify your IT Staff when water bu

15、ilds up in drip pans.Detecting network presence: If upstream components fail, the network can be disconnected from workstations in the business. The system can sense when a network failure occurs. The central monitoring station can contact the IT Staff immediately in the event of a network failure.L

16、og who enters: Because the server can contain sensitive data like employee and payroll records, keeping track of those who enter the server room is a must. The system can track when authorized users enter the server room. It can also notify the monitoring station in the event of forced entry into the server room.Why Honeywell is BetterHoneywells Server Room Supervision