《容量计量器具允许误差》由会员分享,可在线阅读,更多相关《容量计量器具允许误差(1页珍藏版)》请在金锄头文库上搜索。
1、容量计量器具允许误差(摘自JJG196-1990常用玻璃量具)表1.滴定管标称总容量(ml)125102550100分度值(m1)0.010.020.050 10.2容量允差(ml)A级+0.010+0.025+0.04+0.05+0.10B级0.020+0.0500.08+0.10+0.20分度线宽度(mm)W 0.3表2.单标线吸管标称总容量(ml)12351015202550100容量允差(ml)A级+0.007+0.010+0.015+0.020+0.025+0.030+0.05+0.08B级+0.015+0.020+0.030+0.040+0.050+0.060+0.10+0.16分
2、度线宽度(mm)W 0.4表3,分度吸管标称总容量(ml)0.10.20.250.5125102550分度值(ml)0.0010.0050.002 0.010.002 0.010.005 0.01 0020.010.020.050.10.2容量允差(ml)A级+0.008+0.012+0.025+0.05+0.10B级+0.003+0.005+0.010+0.015+0.025+0.050+0.10+0.20吹出式+0.004+0.006+0.008+0.010+0.015+0.025+0.050+0.10分度线宽度(mm)A级(刻线)W 0.3B级(印线)W 0.4表4.单标线容量瓶标称总容
3、量(ml)125510255010020025050010002000容量允差(ml)A级+0 010+0 015+0.020+0.03+0.05+0.10+0.15+0.25+0.40+0.60B级+0.020+0.030+0.040+0.06+0.10+0.20+0.30+0.50+0.80+1.20分度线宽度(mm)W 0.4表5. 量筒标称总容量(ml)510255010025050010002000分度值(ml)0.10.20.52或551020容量允差(ml)量入式+0.05+0.10+0.25+0.5+1.0+2.5+5.0+1.0量出式+0.10+0.20+0.50+1.0+2.0+5.0+10+20分度线宽度(mm)W 0.3W 0.4W 0.5表6.量杯标称总容量(ml)510255010025050010002000分度值(ml)25102550100容量允差(ml)_+02_+04_+05_+10_+15_+30_+60+1B_+20_分度线宽度(mm)W 0.4W 0.5