微软系统工程师考试试题

上传人:cl****1 文档编号:487862086 上传时间:2023-04-19 格式:DOCX 页数:6 大小:15.65KB
返回 下载 相关 举报
微软系统工程师考试试题_第1页
第1页 / 共6页
微软系统工程师考试试题_第2页
第2页 / 共6页
微软系统工程师考试试题_第3页
第3页 / 共6页
微软系统工程师考试试题_第4页
第4页 / 共6页
微软系统工程师考试试题_第5页
第5页 / 共6页
点击查看更多>>
资源描述

《微软系统工程师考试试题》由会员分享,可在线阅读,更多相关《微软系统工程师考试试题(6页珍藏版)》请在金锄头文库上搜索。

1、微软系统工程师考试试题微软系统工程师考试试题微软认证安排进行了全面升级,以涵盖云技术相关的解决方案,并将此类技能的考评引入行业已获得高度认可和备受瞩目的认证考试体系。以下是我整理的关于MCSE微软系统工程师考试试题,希望大家仔细阅读!1. you suspect numerous broadcasts are transmitted at a segment. what program should you use to find out which station is causing this traffic?a. performance monitorb. network monitor

2、 (*)c. server managerd. response probe2. you want to create a capacity-planning baseline of internal resource for your nt server. which tool you use?a. performance monitorb. response probe (*)c. network monitord. excel3. how do you set up a filter in network monitor in order to show traffic generate

3、d from automatic ip adress assignement?a. include * any<->bootpb. protocol=dnsc. protocol=winsd. protocol=dhcp (*)4. you have 4 servers and 500 users. your users need to access the resources at all servers. you need to have centralized account management and administration.what is the most app

4、ropriate domain model?a. single domain model (*)b. master domain modelc. multiple master domaind. complete trust model5. your server has multiple processors installed. which object should be measured if you want only a single line in the graph of performance monitor to represent all processes?a. pro

5、cessor time of the thread objectb. processor time of the process objectc. processor time of the processor objectd. total processor time of the system object (*)6.during printing checks your printer jammed. checks can not be reprinted as it would violate check. the printer is turned off and the jam c

6、leared. how can you print your check again?a. resume from printer menub. resume from document menuc. restart from document menu (*)d. pause printer and restart again7.since you added 7 bdcs to your network, network traffic due todomain synchronization has increased.? this is slowingdown yournetwork.

7、 what should you do to remedy this problem?a. add more bdcsb. increase the value of the pulse concurrency settingsc. increase the value of the pulse setting (*)d. change the replicator governor parameter8.you have a p133, 32mb, 2gb scsi disk configured as file & printserver . your server has slo

8、w response time. network monitor showsthe following figures:object:processor %processor time 88,1%object:memory pages/sec 101, commited bytes 84293object:physical disk %disk time 100 %what should be done:a. upgrade to a second processorb. upgrade to a faster processorc. upgrade memory to 64mb (*)d.

9、implement raid59.what is the cause of the server stop in the event viewer? (exhibitshowing a picture of the event viewer with lots of red marked events.a. ne200 failed (*)b. server service stoptc. cdrom failedd. netlogon failed10.you have the job to make new custom fault tolerance standard foryour c

10、ompany. the company now uses disk duplexing as the currentstandard.required results :data integrity must be maintained when 1 disks fails.optional results :the fault tolerance methode must not use additional processor time.the read access time must be improved.proposed solution :introduce a stripese

11、t with parity. what does the proposed solutionproduce?a. the required result and the optional results.b. the required result and one of the optional results. (*)c. the required result only.d. does not produce the required result.本文来源:网络收集与整理,如有侵权,请联系作者删除,谢谢!第1页 共1页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页第 1 页 共 1 页

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 办公文档 > 解决方案

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号