目 录前言···························································· 1摘要及关键词····················································2第1章 主接线的设计·············································31.1 发电机台数和参数确实定··································31.2 变压器台数和参数确实定·································31.3 厂用电的设计确实定·····································41.4 220kV主接线的设计·····································6第2章 短路电流计算点确实定和短路计算结果······················92.1短路电流计算点确实定····································92.2短路电流计算············································92.3 短路电流计算结果·······································16第3章 主要电气设备的配置和选择································ 163.1主要电气设备的配置······································163.2主要电气设备的选择······································17第4章 所选电气设备的校验······································· 214.1 断路器的校验············································224.2 隔离开关的校验··········································234.3 电流互感器的校验········································234.4 母线的校验··············································25第5章继电保护的配置和考虑······································ 255.1概述·····················································255.2发电机保护配置···········································275.3变压器的保护配置········································29结论·····························································30辞·····························································31参考文献·························································32附录一 所选设备一览表············································33附录二 电气主接线················································35前言毕业设计是我们在校期间最后一次综合训练,它将从思维、理论以及动手能力方面给予我们严格的要求。
使我们综合能力有一个整体的提高它不但使我们稳固了本专业所学的专业知识,还使我们了解、熟悉了国家能源开发策略和有关的技术规程、规定、导则以及各种图形、符号它将为我们以后的学习、工作打下良好的根底能源使社会生产力的重要根底,随着社会生产的不断开展,人类使用能源不仅在数量上越来越多,在品种及构成上也发生了很大的变化人类对能源质量也要求越来越高电力使能源工业、根底工业,在国家建立和国民经济开展中占据十分重要的地位,是实现国家现代化的战略重点电能也是开展国民经济的根底,使一种无形的、不能大量存储的二次能源电能的发、变、送、配和用电,几乎是在同时瞬间完成的,须随时保持功率平衡要满足国民经济开展和要求,电力工业必须超前开展,这是世界开展规律因此,做好电力规划,加强电网建立,就尤为重要而变电站在改变或调整电压等方面在电力系统中起着重要的作用它承担着变换电压、承受和分配电能、控制电力的流向和调整电压的责任222KV变电站电气局部设计使其对变电站有了一个整体的了解该设计包括以下任务:1、主接线的设计 2、主变电压器的选择 3、短路计算 4、导体和电气设备的选择 5、所用电设计摘要:本文首先根据任务书上所给系统与线路及的参数,分析负荷开展趋势。
然后通过对拟建发电厂的概括以及出线来考虑,并通过对负荷资料的分析,平安,经济及可靠性方面考虑,确定了220kV以及厂用电的主接线,然后又确定了主变压器台数,容量及型号,同时也确定了站用变压器的容量及型号,最后,根据最大持续工作电流及短路计算的计算结果,对高压熔断器,隔离开关,母线,绝缘子和穿墙套管,电压互感器,电流互感器进展了选型,从而完成了2×300MW发电厂电气一次局部的设计关键词:发电厂 变压器 主接线第1章 主接线的设计电气主接线是由各种电气设备如:发电机、变压器、断路器、隔离开关、互感器、母线、电缆、线路等按照一定的要求和顺序连接起来,完成电能的输送和分配的电路主接线的好坏不仅影响到发电、变电站和电力系统本身,同时也影响到工农业的生产和人民的正常生活因此,发电厂、变电站的主接线必须满足以下根本要求:1、 保证对必要用户的供电可靠性;2、 接线应力求简单、清晰、操作简便;3、 运行灵活,设备投、停方便,检修、隔离、维护方便;4、 投资少、运行费用低;5、 又扩建的可能性1.1 发电机台数和参数确实定发电机的台数确定为2台,选择型号为:QFSN-300-2,具体参数见下表:型号额定电压额定电流功率因数定子接线负序电抗〔%〕零序电抗〔%〕同步电抗〔%〕次暂态电抗〔%〕QFSN-300-218kV11320A0.852-y23.369.36236.3519.15表1-11.2 变压器台数和参数确实定1.2.1 主变压器台数和参数确实定发电厂主变压器的容量和台数确实定:发电机与主变压器为单元接线时,主变压器的容量可按照以下条件的较大者选择:(1) 按发电机的额定容量扣除本机组的厂用负荷后,留有10%的余度。
2) 按发电机的最续输出容量扣除本机组的厂用负荷 本次电厂的设计采用的是发电机-变压器单元接线,所以容量确实定,根据第一条选择:高压侧电压:242kV 低压侧:18kV主变压器台数和参数选择结果:台数确定为2台,型号为:SFP7-360000/220 具体参数见下表:型号额定容量〔kVA〕额定高压〔kV〕额定低压〔kV〕连接组别阻抗电压(%)SFP7-360000/2203600002422×2.5%18YN,d1114.3表1-21.3 厂用电的设计确实定1.3.1 厂用电压等级确实定 经技术经济比较,我国有关技术规定中指定厂用电压确实定原则如下:发电厂可采用3kV、6kV、10kV作为厂用电电压发电机容量为100~300MW的机组宜采用6kV所以本次发电厂设计的厂用电电压等级为:6kV1.3.2 厂用电源及其引接方式〔1〕厂用工作电源及其引接方式发电机额定功率为200MW及以上时,一般采用单元接线,这时厂用电源一般从发电机组出口或变压器低压侧引接,如以下列图所示:由于发电机容量为200MW及以上的发电机组引出线及厂用分支采用封闭母线,封闭母线发生相间短路故障的时机很少,因此厂用分支不可装设断路器,但应有可靠的可拆连接点以便满足检修调试的要求。
图1-1 厂用电源引接方式〔2〕启动备用/电源的取得当工作电源故障时,应由备用电源继续向厂用电负荷供电启动电源完全消失时,保证机组重新启动的厂用电源一般容量在200MW及以上机组需要设置启动电源高压厂用备用变压器的引接线应遵循以下原则:1) 当设有发电机电压母线时,可由于工作电源不同的分段上引出2) 当无发电机电压母线时,由与电力系统连接可靠的最低一级电压母线上引出,或由联络变压器的第三〔低压〕绕组引出,并应保证在发电厂全厂停电的情况下,能从电力系统取得足够的电源3) 有两个及以上的备用电源时应由两个相对独立的电源引出4) 在技术经济条件许可的情况下,可由外部电网接一条专用线路供电本厂设计方案为1.3.3 厂用变压器容量参数的选择和确定1〕厂用工作变的选择厂用工作变的台数确定为2台,选分裂绕组变压器,高压侧电压:18kV 低压侧电压:6.3kV容量确实定:选择结果:型号 SFF7-40000/18具体参数见下表:表1-3型号容量〔kVA〕高压〔kV〕低压〔kV〕全穿越电抗〔%〕半穿越电抗〔%〕连接组别SFF7-40000/1840000/2×20000182×2.5%8.0115.06D,d0,d0表1-32〕厂用起备变的选择厂用起备变的台数确定为1台,选分裂绕组变压器;高压侧电压:220kV 低压侧电压:6.3kV容量确实定:选择结果:型号 SFPFZ-40000/220具体参数见下表:型号容量〔kVA〕高压〔kV〕低压〔kV〕全穿越电抗〔%〕半穿越电抗〔%〕连接组别SFPFZ-40000/22040000/2×200002208×1.25%025YN,d11,d11表1-41.4 220kV主接线的设计1.4.1 方案一:采用双母线接线 如图1-2图1-2 220kV双母线接线双母线的两组母线同时工作,并通过母联断路器并联运行,电源与负荷平均分配再亮组母线上。
由于母线继电保护的要求,一般*一回路固定于*一母线连接,以固定连接的方式运行〔1〕优点1〕供电可靠通过两组母线隔离开关的倒闸操作,可以轮流检修一组母线而不致使供电中断;一组母线故障后,能迅速恢复供电;检修任意回路的的母线隔离开关只停该回路2〕调度灵活各个电源和各回路负荷可以任意分配到*一组母线上,能灵活地适应系统中各种运行方式调度和潮流变化的需要3〕扩建方便向双母线的左右任何一个方向扩建,均不影响两组母线的电源和负荷均匀分配,不会引起原有回路的停电当有双回线路布置时,可以顺序布置,以致连接不同的母线段时,不会如单母线分段那样导致出现穿插跨越4〕便于试验当个别回路需要单独进展试验时,可将该回路分开,单独接至一组母线上〔2〕缺点1〕增加一组母线和使每回路就要增加一组母线隔离开关2〕当母线检修或故障时,隔离开关作为倒换操作电器,容易误操作为了防止误操作,需要在隔离开关和断路器之间装设连锁装置〔5〕适用围: 当出线回路数或母线上电源较多、输送和穿越功率较大、母线故障后要求迅速。