1、Page 1/9 SERVICE MANUAL Manual No. SE-CL201AX05-01 Machine CL1500 CL2000 Controller MSX-805 MSG-805 MSC-805 Component Axis Drive Title Adjustment of Zero Return Position for Z-Axis 3 2 1 2007/2/16 New Version Sakai Version YY /MM /DD Changes Corrected By Specified Production Month Approval Issued By

2、 Machines From October 2000 (No.1) Yoshida Sakai CF2165-901A-02 For Electronic For Electronic DistributionDistribution Z-axis zero return position adjustment is required following servomotor/pulse-coder replacement or loss of parameter data. “ Z70 ABS. ILLEGAL 000n Z ” is displayed on the NC ALARM s

3、creen. Establishment of the Z-axis zero return position is necessary. Establishment and Adjustment of the zero return position for Z-axis using following procedure. Determinant of Z-axis zero return position based on Spindle Large Nose. For checking distance from Spindle Large Nose to zero return po

4、sition, need to remove the chuck from the machine. So this manual considers zero point reference indexes (zero point index marks) is Z-axis zero return position. (Refer to on last pages about exact distance from Spindle Large Nose to zero return position.) 1. Set the “ ZERO POINT ADJUSTMENT ” to “ V

5、ALID ” on OPERATION PANEL screen to enable axis travel. 2. Position the Z-axis to the machine zero point (Z-axis zero point index marks matches). 3. Display the ABS. POSITION SET (Absolute Position Set) screen. 4. Perform Z-axis initial setting on ABS. POSITION SET screen. 5. Set the Z-axis “ ORIG-R

6、TN ” (Origin Return) on ABS. POSITION SET screen. 6. Establish of the Z-axis zero return position. 7. Reset the NC power following zero return position establishment. 8. Following power on, perform Z-axis zero return operation to confirm positioning. 9. Check the operation of the Z-axis in both of M

7、anual and MDI operation. No. NC ALARM MESSAGE Z70 ABS. ILLEGAL 000n Z SERVICE MANUAL SE-CL201AX05-01 Page2/9 Title Adjustment of Zero Return Position for Z-Axis CF2165-901A-02 1. When “ Z70 ABS. ILLEGAL 000n Z ” is displayed on the NC ALARM screen, set the “ ZERO POINT ADJUSTMENT ” to “ VALID ” on O

8、PERATION PANEL screen in according to the following steps 1.1 1.5. When changing zero return position (NC alarm not displayed), go to step 2. In the case of MSG-805, 803 (machine with former type of MAPPS operation panel): Press SETTING function key function key F1 “ OPE. PANEL ” to display the OPER

9、ATION PANEL screen, and set the “ ZERO POSITION SET ” to “ VALID ”. 1.1 Press the SETTING function key to display the SETTING screen. 1.2 Press the F1 “ OPE. PANEL ” (Operation Panel) function key on SETTING screen. 1.3 The function key menu is changed as indicated below. Press the F6 “ OPE PANEL ”

10、function key to display the OPERATION PANEL screen. 1.4 Move the cursor to the “ ZERO POINT ADJUSTMENT ” using cursor movement keys on OPERATION PANEL screen. 1.5 When the cursor is aligned with “ ZERO POINT ADJUSTMENT ”, press the cursor movement key to select “ VALID ”. (“ VALID ” is highlighted)

11、SETTING OPE. PANEL FF F FF 12 345 SET NETWORK PARAM. TIMER COUNTER OPE PANEL F F F FF 78 9106 - - - - - BLOCK DELETE - - - - - OPE. MODE OPERATION PANEL CHUCK FOOT SWITCH AT DOOR CLOSEINVALID VALID CHUCK 1 STROKE END CONFIRMATION SWITCHVALID ZERO POINT ADJUSTMENT INVALID INVALIDVALID CHUCK FOOT SWIT

12、CHVALID INVALID SERVICE MANUAL SE-CL201AX05-01 Page3/9 Title Adjustment of Zero Return Position for Z-Axis CF2165-901A-02 2. Position the Z-axis to the machine zero point in according to the following steps 2.1 2.3. 2.1 Press the H (Handle) mode selection switch to select the Handle mode. 2.2 Move t

13、he Z-axis to the machine zero point (where Z-axis zero point index marks matches) using manual pulse generator. In the case of no zero point index marks and checking the zero return position using the distance from the spindle large nose, refer to on the last page. 2.3 Set the Z-axis “ RELATIVE COOR

14、DINATE ” value to “ 0.000 ” at the Z-axis machine zero point in according to the following steps 2.3.1 2.3.3. 2.3.1 Press the POS (Position) function key to display the CURRENT POSITION screen. 2.3.2 Press the F2 “ REL. ” (Relative) function key on CURRENT POSITION screen to display the “ RELATIVE C

15、OORDINATE ” screen. 2.3.3 Input W J (relative coordinate of Z-axis) using data input keys and press the F10 “ ORIGIN ” function key on “ RELATIVE COORDINATE ” screen. The W-axis coordinate value (Z-axis relative coordinate value) is set to “ 0.000 ”. The position traveled by the Z-axis is to be esta

16、blished as the Z-axis zero return position. Do not move the Z-axis until zero return position establishment is completed. The position traveled by the Z-axis is to be established as the Z-axis zero return position. Do not move the Z-axis until zero return position establishment is completed. Saddle Right Side Cover Z-axis Zero Point Index Mark ABS. FF F FF 12 345 REL. ALL MONITOR RELATIVE COORDINATE F F F FF