1、00E-1 GROUP 00E GENERAL CONTENTS HARNESS CONNECTOR INSPECTION . . . . . . . . . . . . . . . . . . .00E-2 HOW TO DIAGNOSE HOW TO DIAGNOSE . . . . . . . . . . . . . . . . . 00E-6 TROUBLESHOOTING STEPS. . . . . . . . . . 00E-6 INFORMATION FOR DIAGNOSIS . . . . . . . 00E-6 INSPECTION . . . . . . . . . .

2、 . . . . . . . . . . . . . 00E-7 INSPECTION INSTRUMENTS . . . . . . . . . . 00E-8 CHECKING FUSES. . . . . . . . . . . . . . . . . . . 00E-9 CHECKING SWITCHES . . . . . . . . . . . . . . . 00E-10 CHECKING RELAYS . . . . . . . . . . . . . . . . . 00E-11 CABLES AND WIRES CHECK . . . . . . . . . . 00E-1

3、2 BATTERY HANDLING . . . . . . . . . . . . . . . . 00E-12 GENERAL ELECTRICAL SYSTEM CHECK00E-13 HARNESS CONNECTOR INSPECTION TSB Revision GENERAL 00E-2 HARNESS CONNECTOR INSPECTION M1001003900201 CONNECTOR CONTINUITY AND VOLTAGE TEST Required Special Tools: MB991219: Test Harness Set MD998459: Test

4、Harness Follow the steps below to avoid causing poor connector contact and/or reduced waterproof performance of connectors when checking continuity and/or voltage at waterproof connectors. AC000014AB MD998459 CAUTION Never backprobe a waterproof connector. Backprobing a connector may cause the termi

5、nals to corrode, deteriorat- ing circuit performance. 1. If the circuit to be checked is a closed state, use a special tool like MD998459. AC000015 AB MB991219 CAUTION Forcing the probe into the terminal may open the terminal, causing intermittent or poor contact and creating an open circuit. 2. If

6、the connector is disconnected for checking and the facing part is the female pin side, use an appropriate male terminal for checking the contact pressure of connector pins (like MB991219). CAUTION Do not simultaneously contact more than one terminal with the probe. Contacting two or more terminals a

7、t the same time may damage a circuit, possibly to the point of starting an electrical fire. 3. If the facing part is the male pin side, either carefully touch the probe to the pin so it does not accidently contact other pins, or use an appropriate female terminal. IMPROPER TERMINAL ENGAGEMENT CHECK

8、AC000016 Terminals inside a connector may not engage properly even if the connectors engage. Make sure that each terminal does not come out of the connector when gently pulling each harness wire. If it does, repair or replace the terminal and/or connector. HARNESS CONNECTOR INSPECTION TSB Revision G

9、ENERAL 00E-3 CONNECTOR TERMINAL ENGAGEMENT AND DISENGAGEMENT Loosely engaged terminals can be repaired by removing the female terminal from the connector housing and raising its lance to establish better engagement. Removal of the connec- tor terminal used for MFI and INVECS-II A/T control circuit c

10、an be done in the following manner. . COMPUTER CONNECTOR ACX00904AB FRONT HOLDER FRONT HOLDER 1. Insert a screwdriver 1.4 mm (0.06 inch) width as shown in the figure, disengage the front holder, and remove it. ACX00905 2. Push the harness wire of the terminal to be repaired deep into the connector f

11、rom the harness side and hold it there. AC310118 HOUSING LANCE AB 3. Insert the tip of the screwdriver 1.4 mm (0.06 inch) width into the connector as shown in the figure, gently push the housing lance down with the tip, and pull out the terminal. ACX00907AB NEEDLE NEEDLE 4. Insert a needle through t

12、he hole provided on the terminal and raise the contact point. Lightly squeeze the outer edge so the flats are parallel with the bottom. . HARNESS CONNECTOR INSPECTION TSB Revision GENERAL 00E-4 ROUND WATERPROOF CONNECTOR ACX00908AB HOUSING LANCE 1. Remove the waterproof cap by using a screwdriver. 2

13、. Insert the tip of the screwdriver 1.4 mm (0.06 inch) or 2.0 mm (0.08 inch) width into the connector as shown in the figure, raise the housing lance slightly with the tip, and pull out the terminal. ACX00909 3. Insert a screwdriver through the hole provided on the terminal and raise the contact poi

14、nt. Lightly squeeze the outer edge so the flats are parallel with the bottom. . RECTANGULAR WATERPROOF CONNECTOR ACX00910AB FRONT HOLDER FRONT HOLDER 1. Disengage the front holder with a screwdriver and remove it. ACX00911AB HOUSING LANCE 2. Insert the tip of a screwdriver 0.8 mm (0.03 inch) width i

15、nto the connector as shown in the figure, push it lightly to raise the housing lance, and pull out the terminal. ACX00912 HARNESS CONNECTOR INSPECTION TSB Revision GENERAL 00E-5 3. Press the contact point to the male terminal down by holding a screwdriver 1.4 mm (0.06 inch) width as shown in the fig

16、ure. Lightly squeeze the outer edge so the flats are parallel with the bottom. . INJECTOR CONNECTOR ACX00913AB WATERPROOF CAP 1. Remove the waterproof cap. AC310304AB TERMINAL LANCE 2. Insert the tip of a screwdriver 1.4 mm (0.06 inch) width into the connector as shown in the figure, press in the terminal lance, and pull out the terminal. AC310313 CAUTION Make sure the lance is pressed in before the terminal is inserted into the connector. 3. Press the contact point to the male