超滤管说明书——产品说明书

上传人:第*** 文档编号:56561912 上传时间:2018-10-13 格式:PDF 页数:30 大小:821.27KB
返回 下载 相关 举报
超滤管说明书——产品说明书_第1页
第1页 / 共30页
超滤管说明书——产品说明书_第2页
第2页 / 共30页
超滤管说明书——产品说明书_第3页
第3页 / 共30页
超滤管说明书——产品说明书_第4页
第4页 / 共30页
超滤管说明书——产品说明书_第5页
第5页 / 共30页
点击查看更多>>
资源描述

《超滤管说明书——产品说明书》由会员分享,可在线阅读,更多相关《超滤管说明书——产品说明书(30页珍藏版)》请在金锄头文库上搜索。

1、Amicon Ultra-15 Centrifugal Filter Devicesfor volumes up to 15 mLUser GuideAmicon Ultra-15 10K device for in vitro diagnostic useAmicon Ultra-15 3K, 30K, 50K, and 100K devices for research use only; not for use in diagnostic procedures PR02842_RevB.indd 2910/30/2009 11:42:29 AMNotice The information

2、 in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation or an affiliated corporation. Neither Millipore Corporation nor any of its affiliated corporations assumes responsibility for any errors that may appear in this document. This m

3、anual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual. 2009 MILLIPORE CORPORATION. ALL RIGHTS RESERVED.PR02842 Rev. B, 10/09Millipor

4、e, Amicon, Centricon, Milli-Q, MultiScreen, and Ultracel are registered trademarks of Millipore Corporation. The M mark is a trademark of Millipore Corporation. Alconox and Terg-A-Zyme are registered trademarks of Alconox, Inc. Lubrol is a registered trademark of Imperial Chemical Industries PLC. No

5、nidet is a trademark of Royal Dutch/Shell Group. Triton is a registered trademark of Union Carbide Corporation. Tween is a registered trademark of ICI Americas, Inc.PR02842_RevB.indd 3010/30/2009 11:42:29 AMContentsIntroduction 1 Applications .2 Materials Supplied .3 Required Equipment 4 Suitability

6、 .4 Device Storage 4 Specifications 5 Chemical Compatibility 7 How to Use Amicon Ultra-15 Centrifugal Filter Devices .9 How to Quantitate Recoveries .10 Performance - Protein Concentration 13 Flow Rate.13 Protein Retention and Concentrate Recovery18 Maximizing Sample Recovery .21 Desalting or Diafil

7、tration .22 Centrifugal Product Ordering Information 23 Technical Assistance .24 In Vitro Diagnostic Product Labeling 25 Standard Warranty .26PR02842_RevB.indd 3110/30/2009 11:42:29 AMIntroductionMillipores Amicon Ultra-15 centrifugal filter devices provide fast ultrafiltration, with the capability

8、for high concentration factors and easy concentrate recovery from dilute and complex sample matrices. The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold

9、concentration. Typical processing time is 15 to 60 minutes depending on Nominal Molecular Weight Limit (NMWL). Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential samp

10、le loss. The concentrate is collected from the filter device sample reservoir using a pipettor, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. Amicon Ultra-15 devices are supplied non-sterile and are for single

11、use only.PR02842_RevB.indd 110/30/2009 11:42:26 AMIntroduction, continuedThe Amicon Ultra-15 product line includes 5 different cutoffs (Nominal Molecular Weight Limit, NMWL, or Molecular Weight Cutoff, MWCO): Amicon Ultra 3K device 3,000 NMWL Amicon Ultra 10K device 10,000 NMWL Amicon Ultra 30K devi

12、ce 30,000 NMWL Amicon Ultra 50K device 50,000 NMWL Amicon Ultra 100K device 100,000 NMWL Amicon Ultra-15 10K filter devices are for in vitro diagnostic use and can be used to concentrate serum, urine, cerebrospinal fluid, and other body fluids prior to analysis. Amicon Ultra-15 3K, 30K, 50K, and 100

13、K filter devices are for research use only and not for use in diagnostic procedures. ApplicationsConcentration of biological samples containing antigens, antibodies, enzymes, nucleic acids (DNA/RNA samples, either single- or double-stranded), microorgan- isms, column eluates, and purified samplesPR0

14、2842_RevB.indd 210/30/2009 11:42:26 AMAmicon Ultra-15 Centrifugal Filter Devices3Applications, continuedPurification of macromolecular components found in tissue culture extracts and cell lysates, removal of primer, linkers, or molecular labels from a reaction mix, and protein removal prior to HPLC

15、Desalting, buffer exchange, or diafiltration Materials SuppliedFilter deviceCentrifuge tubeCap The Amicon Ultra-15 device is supplied with a cap, a filter device, and a centrifuge tube.PR02842_RevB.indd 310/30/2009 11:42:27 AMRequired EquipmentCentrifuge with swinging bucket or fixed angle rotor with wells/carriers that can accommodate 50 mL tubesCAUTION: To avoid damage to the device during centrifugation, check clearance before spinning. Pipettor with 200 microliter (L) tip for concentrate recovery SuitabilityPreliminary recovery and retention studies are suggested to ensure su

展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 办公文档 > 调研报告

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号