1、Introduction to ECLIPSE 100Introduction to ECLIPSE 100FAQReferencesSummaryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUseful InformationsRunning SimulationSample SimulationVisualization SoftwareHome ContentsKeywords in SectionsUseful InformationsSample SimulationVisualization

2、Software General Informations Section-header Keywords GRAF Excel GLview What is it ECLIPSE 100? How to start? Input data fileRunning SimulationFAQReferencesSummaryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUseful InformationsRunning SimulationSample SimulationVisualization So

3、ftwareGeneral InformationsECLIPSE 100 is a fully-implicit, three phase, three dimensional, general purpose black oil simulator with gas condensate option.Program is written in FORTRAN77 and operate on any computer with an ANSI-standard FORTRAN77 compiler and with sufficient memory.ECLIPSE 100 can be

4、 used to simulate 1, 2 or 3 phase systems. Two phase options (oil/water, oil/gas, gas/water) are solved as two component systems saving both computer storage and computer time. In addition to gas dissolving in oil (variable bubble point pressure or gas/oil ratio), ECLIPSE 100 may also be used to mod

5、el oil vaporizing in gas (variable dew point pressure or oil/gas ratio).Both corner-point and conventional block-center geometry options are available in ECLIPSE. Radial and Cartesian block-center options are available in 1, 2 or 3 dimensions. A 3D radial option completes the circle allowing flow to

6、 take place across the 0/360 degree interface.What is it ECLIPSE 100?FAQReferencesSummaryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUseful InformationsRunning SimulationSample SimulationVisualization SoftwareGeneral InformationsHow to start?To run simulation you need an input

7、 file with all data concerning reservoir and process of its exploitation.Input data for ECLIPSE is prepared in free format using a keyword system. Any standard editor may be used to prepare the input file. Alternatively ECLIPSE Office may be used to prepare data interactively through panels, and sub

8、mit runs.The name of input file has to be in the following format: FILENAME.DATAFAQReferencesSummaryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUseful InformationsRunning SimulationSample SimulationVisualization SoftwareGeneral InformationsAn ECLIPSE data input file is split i

9、nto sections, each of which is introduced by a section-header keyword. A list of all section-header keywords is given in following, together with a brief description of the contents of each section and examples of keywords using in file code.The keywords in the input data file (including section-hea

10、der keywords) are each of up to 8 characters in length and must start in column 1. All characters up to column 8 are significant. Any characters on the same line as a keyword from column 9 onwards will be treated as a comment.Note that all keywords in input file have to be in proper orderRead more a

11、bout basic principles of computer modeling in Reservoir Simulation e-learning modules or on website: http:/iptibm3.ipt.ntnu.no/kleppe/Use frame command under UNIX system to read Reference ManualInput data fileFAQReferencesSummaryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUsef

12、ul InformationsRunning SimulationSample SimulationVisualization SoftwareSection-header keywordsThe list of section-header keywords in proper order:RUNSPECGRIDPROPSREGIONSSOLUTIONSUMMARYSCHEDULEThe sections must be specified in the shown order. It may be helpful to use a mnemonic to remember the orde

13、r (for example RUth GReets EDgar PROPerly at REGgies SOcial SUMMer SCHool).It is recommended that the body of sections which are not frequently changed be held in separate files which are included in the data using the INCLUDE keyword.A data record has to be ended with a slash /EDITFAQReferencesSumm

14、aryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUseful InformationsRunning SimulationSample SimulationVisualization SoftwareSection-header keywordsStatus:REQUIREDBack to list of section-header keywordsTitle, problem dimensions, switches, phases present, components etc.GRID Stat

15、us:REQUIREDRUNSPECThe GRID section determines the basic geometry of the simulation grid and various rock properties (porosity, absolute permeability, net-to-gross ratios) in each grid cell. From this information, the program calculates the grid block pore volumes, mid-point depths and inter-block tr

16、ansmissibilities.FAQReferencesSummaryInfoSection-header KeywordsKeywords in SectionsGeneral InformationsUseful InformationsRunning SimulationSample SimulationVisualization SoftwareSection-header keywordsEDIT Status:OPTIONALBack to list of section-header keywordsModifications to calculated pore volumes, grid block centre depths and transmissibilities.PROPS Status:REQUIREDTables of properties of reservoir r