1、ROC Permanent Monitoring Systems 2010 Halliburton. All Rights Reserved.2WellDynamics: Transforming Reservoirs with SmartWell System Technology Our mission To be the premier provider of intelligent completion technology, creating value for our customers by delivering fit-for-purpose, innovative and r

2、eliable solutions for zonal isolation and flow control, reservoir monitoring, fiber optic and surface digital infrastructureFlow ControlFiber OpticsPermanent MonitoringDigital Infrastructure 2010 Halliburton. All Rights Reserved.3Permanent Monitoring: Applications Optimized Production Analyze pressu

3、re losses Accelerate production Obtain data from unplanned shutdowns Monitor formation damage through well transients Optimize artificial lift Optimize sand control and stimulation Reservoir Management Improve understanding of the reservoir and quality of reservoir description Predict future product

4、ion/ recovery for various development strategies Improve reserves calculation and optimize production of recoverable reserves Receive early data on actual vs predicted performance Pressure TemperatureSmartWell System CompletionSCADA/DCSValve CommandsDecisionSmartWell System CompletionSCADA/DCSFirst

5、Principles Simulation(s)Predictive ModelOptimizerLandmark WellSolver 2010 Halliburton. All Rights Reserved.4Permanent Monitoring Components 2010 Halliburton. All Rights Reserved.5Track Record & ReliabilityPermanent Monitoring Reliability R(60)ROC Permanent Monitoring SystemsSystems installed731ROC P

6、DGs 1164ApplicationsLand258Platform441Subsea465 2010 Halliburton. All Rights Reserved.6ROC Environmental Operating EnvelopeROC-H 10K 150C 9381-6010ROC-H 16K 177C TBDROC-H 20K 200C 9381-6012ROC-H 25K 200C 9381-6013ROC-H 30K 200C TBDROC-HROC-150 SeriesROC-175 SeriesROC-200 Series 2010 Halliburton. All

7、 Rights Reserved.7ROC Environmental Operating EnvelopeROC-H 10K 150C 9381-6010ROC-H 16K 177C TBDROC-H 20K 200C 9381-6012ROC-H 25K 200C 9381-6013ROC-H 30K 200C TBDROC-HROC-300ROC-350ROC-400ROC-150 10KROC-175 16KROC-175 20KROC-175 25KROC-200 25KROC-200 20KROC-200 30K 2010 Halliburton. All Rights Reser

8、ved.8ROC Gauge VariantsROC dualROC dual P/T sensorP/T sensorROC dual ROC dual P/T sensor P/T sensor plus feedthroughplus feedthroughROC fully redundantROC fully redundant P/T sensor P/T sensor plus feedthroughplus feedthroughROC singleROC single P/T sensor, P/T sensor, plus feedthroughplus feedthrou

9、ghROC singleROC single P/T sensorP/T sensorROC fully ROC fully redundantredundant P/T sensorP/T sensorNote: Fully redundant configurations contain dual electronics and dual sensors ported to a single pressure port 2010 Halliburton. All Rights Reserved.9ROC - Standard Gauge Configurations 2010 Hallib

10、urton. All Rights Reserved.10ROC Permanent Downhole GaugesCable termination (field-pressure testable)PCB/hybridMechanical arrangement, including sealsPressure/temperature quartz transducer 2010 Halliburton. All Rights Reserved.11HPHT Environments: ROC Permanent Downhole Gauge Quartz sensor-based des

11、ign High accuracy (0.02% FS) High resolution ( 90% 5 yrs 180C 3” 2010 Halliburton. All Rights Reserved.12ROC Hybrid AdvantagesLong-term reliability at extreme temperatures Excellent heat dissipation over traditional downhole electronics Improved thermal shock resistance Improved physical shock and v

12、ibration resistance Compact size 2010 Halliburton. All Rights Reserved.13Qualification Testing Completed Electronic Circuit Testing Verified functionality from 0C to 220C Telemetry Performance Determined telemetry performance at 35,000ft cable length Noise Tolerance Testing Confirmed telemetry perfo

13、rmance in high noise environment HALT Testing Lifetime testing including combined environment testing Weld and Seal Testing Testing of seal performance at elevated pressure and temperature QALT Testing Determine lifetime estimates as a function of temperature 2010 Halliburton. All Rights Reserved.14

14、ROC Lifetime Estimates 2010 Halliburton. All Rights Reserved.15Gauge Mandrels Slimline design Machined from solid billet No welded parts Ultrasonic wall thickness test API 5CT standard Body burst test Gauge mandrel pressure test Multiple seals Full component protection Line bypass slots 2010 Hallibu

15、rton. All Rights Reserved.16Single Gauge Mandrel 2010 Halliburton. All Rights Reserved.17Dual Gauge Mandrel 2010 Halliburton. All Rights Reserved.18Triple Gauge Mandrel 2010 Halliburton. All Rights Reserved.19FloStream Venturi Flowmeter Mandrel 2010 Halliburton. All Rights Reserved.20Tubing Encased

16、Conductor (TEC) TEC (Tubing Encased Conductor) Alloy 825 & Stainless Steel Wall thickness: 0.028”, 0.035” & 0.049” Up to 34,000 ft Insulator ratings: 135C / 275F, 150C / 302F, 200C / 392F Heavier wall options preferred Reduce handling risk at tubing hanger Higher pressure rating Better sealing Higher tensile strength Highe