1、3 Pneumatically Actuated Valves3 / 002Pneumatic Actuator Selection Guide3 / 003Pneumatically Actuated Two-Way Brass Ball Valves3 / 004Pneumatically Actuated Three-Way Brass Ball Valves3 / 005Pneumatically Actuated Two-Way Stainless Steel Ball Valves3 / 006Pneumatically Actuated Three-Piece Stainless

2、 Steel Ball Valves3 / 007Pneumatically Actuated Three-Way Stainless Steel Ball Valves3 / 008Pneumatically Actuated Two-Way Flanged Wafer Ball Valves - Stainless Steel3 / 009Pneumatically Actuated Butterfly Valves - Wafer Type Cast Iron with Stainless Steel Disc3 / 010Pneumatically Actuated Butterfly

3、 Valves - Lugged Type Cast Iron with Stainless Steel Disc3 / 011Valbia Pneumatic Actuator - Accessories -0123Pneumatic Actuator Selection GuidePNEUMATICALLY ACTUATED VALVESThe company reserves the right to vary models and dimensions without notice. These products are designed for industrial applicat

4、ions and are not suitable for sale to the general public.PNEUMATICALLY ACTUATED VALVES3.00002INDUSTRIAL VALVES CATALOGUE RELEASE 1.03Cannot find what you are looking for? Call: +44 (0)24 7653 4535The following pages show various Ball Valves and Butterfly valves fitted with the Valbia Pneumatic actua

5、tor. All actuator sizes shown on the following pages have been calculated based on the following criteria :-1) A minimum pilot air supply pressure to the actuator of 5.5 Bar g 2) The medium being Water at a pressure of 10 Bar g and a temperature of 20OC.In the event that your application differs fro

6、m the above, then it may be necessary to fit a larger actuator to operate the valve. The following is intended as a guide to assist with actuator selection. If you require any technical assistance please do not hesitate to contact the Bonomi UK Ltd Technical Department. We are always happy to help.Q

7、uestion 1 - Double Acting or Spring Return actuator ?A Double Acting actuator will require two air supplies, 1 to drive the actuator / valve to the closed position and 1 to return it to the open position. This type is known as Fail Fixed because if the air supply is lost, the actuator will stop at t

8、he position reached prior to the loss of air.A Spring Return actuator only requires 1 air supply which is normally used to drive the actuator / valve to the Open position. When the air supply is lost the springs inside the actuator drive it / the valve in to the Closed position. This is known as Air

9、 Fail Closed / Normally Closed. For Air Fail Open / Normally Open actuator the air supply is used to drive the actuator / valve to the closed position with the springs driving it Open on loss of air. Please confirm the required Fail position.Question 2 - Confirm minimum pilot air pressure available

10、for the actuator ?This is very important. A pneumatic actuator produces less torque the lower the pilot air supply and hence a larger actuator may be required to operated the valve. All Valbia actuators are suitable for a maximum pilot air supply pressure of 8 Bar g.Question 3 What is the Medium, Wo

11、rking Pressure and Working temperature ?This is needed to ensure correct sizing of the actuator. As mentioned above all actuators shown on the following pages have been sized based on the medium being Water at a pressure of 10 Bar g and a temperature of 20OC. If the medium is at a high pressure, is

12、viscose (tar / treacle like), is in powder form (cement etc) or a is a dry gas (usually a hot gas) then the actuator will have to be sized accordingly. This is because any of the above will lead to an increase in the valve torque figure meaning that a larger actuator will invariably be required to o

13、perate the valve. High Temperature applications may require that the valve be fitted with seats of a special material which is suitable for the working temperature. This will also usually cause an increase in the valve torque figure meaning that a larger actuator may be required to operate the valve

14、. Also, on high temperature applications it may be necessary to fit a non standard extended valve to actuator mounting bracket. This is required to raise the actuator above the heat source to prevent any damage to the actuator seals. The mounting bracket height will be calculated based on the workin

15、g temperature - please contact the Bonomi UK Ltd Technical Department for assistance.Question 4 - Are any ancillaries required ?Such as a pilot solenoid valve, switchbox, filter regulator or positioner etc. Always ask your customer if any ancillary equipment is required. There are far too many optio

16、ns to list so please contact the Bonomi UK Ltd Technical Department for assistance.Question 5 Is the equipment is to be used in a Hazardous Area ?All of the Valbia actuators are ATEX approved for use in a hazardous area. We can offer any ancillaries suitable for use in all hazardous areas. Please ask your customer to confirm exact hazardous area requirements (ATEX, BASEEFA, CENELEC etc).2-way brass ball valve (2500) with chrome plated ball, threaded F/F with P