澳大利亚电缆标准

上传人:wt****50 文档编号:46596256 上传时间:2018-06-27 格式:PDF 页数:45 大小:919.85KB
返回 下载 相关 举报
澳大利亚电缆标准_第1页
第1页 / 共45页
澳大利亚电缆标准_第2页
第2页 / 共45页
澳大利亚电缆标准_第3页
第3页 / 共45页
澳大利亚电缆标准_第4页
第4页 / 共45页
澳大利亚电缆标准_第5页
第5页 / 共45页
点击查看更多>>
资源描述

《澳大利亚电缆标准》由会员分享,可在线阅读,更多相关《澳大利亚电缆标准(45页珍藏版)》请在金锄头文库上搜索。

1、AS/NZS 1429.1:2006 Australian/New Zealand StandardElectric cablesPolymeric insulated Part 1: For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kVAS/NZS 1429.1:2006 AS/NZS 1429.1:2006 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL-003, Elect

2、ric Wires and Cables. It was approved on behalf of the Council of Standards Australia on 3 April 2006 and on behalf of the Council of Standards New Zealand on 31 March 2006. This Standard was published on 21 April 2006. The following are represented on Committee EL-003: Australasian Railway Associat

3、ion Australian Electrical and Electronic Manufacturers Association Australian Industry Group Canterbury Manufacturers Association New Zealand Department of Primary Industries, Mine Safety (NSW) Electrical Contractors Association of New Zealand Electrical Regulatory Authorities Council Energy Network

4、s Association Engineers Australia Ministry of Economic Development (New Zealand) Keeping Standards up-to-date Standards are living documents which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published.

5、 Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased. Detailed information about joint Austral

6、ian/New Zealand Standards can be found by visiting the Standards Web Shop at .au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in the on-line catalogue. Alternatively, both organizations publish an annual printed Catalogue with full details of all curr

7、ent Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their respective national Standards organization. We also wel

8、come suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comments to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the back cover.

9、 This Standard was issued in draft form for comment as DR 05363. AS/NZS 1429.1:2006 Australian/New Zealand StandardElectric cablesPolymeric insulated Part 1: For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kVCOPYRIGHT Standards Australia/Standards New Zealand All rights are rese

10、rved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher. Jointly published by Standards Australia, GPO Box 476, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2439,

11、Wellington 6020 ISBN 0 7337 7385 0 Originated as AS 14291979. Jointly revised and designated AS/NZS 1429.1:2000. Third edition 2006. AS/NZS 1429.1:2006 2 PREFACE This Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL-003, Electric Wires and Cables, to supersed

12、e AS/NZS 1429.1:2000. This Standard differs from the previous edition in the following significant ways: (a) The range of conductor sizes has been expanded to 1 600 mm2.(b) The method of specifying the thickness of insulation, separation sheath, metal sheath and oversheath has been aligned with IEC

13、60502-2. (c) MDPE has replaced PE as an optional oversheathing material. (d) Cables with collectively screened constructions are no longer specified. (e) The requirement for a qualification test report has been added. (f) The range of approval has been modified. (g) The recommended diameter of drum

14、barrel and minimum installation bending radius has been extended to cover triplex cables. (h) The sample test requirement has become mandatory. In the preparation of this Standard, consideration was given to the following publications and acknowledgment is made of the assistance received: IEC 60502-

15、2, Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV), Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)IEC 60811, Common test methods for insulating and sheathing materials of electric cabl

16、es and optical cables (all Parts)The nominal cross-sectional areas of the conductors specified herein are identical with the values specified in AS/NZS 1125, Conductors in insulated electric cables and flexible cords.The dimensions for insulation and oversheath thicknesses are identical with the values recommended in IEC 60502. Certain tests and criteria in this Standard are more stringent than those in IEC 60502. Two