1、Cat. No. Z207-E1-01USER MANUALSmart Sensors ZFV Series?IntroductionSection 1 Section 2 Section 3 Section 4INTRODUCTIONSECTION 1SECTION 2SECTION 3SECTION 4?Users ManualSmart Sensors with Ultra-high-speed CCD Camera ZFV SeriesAPPLICATION CONSIDERATIONS (Please read first)FEATURESINSTALLATION however,

2、no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the users programming of a programmable product, or any consequence thereof.COPYRIGHT AND COPY PERMISSION This document shall not be copied for sale

3、s or promotions without permission.This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please co

4、py or transmit it in its entirety.4IntroductionZFV Users ManualIntroduction Precautions for Safe UsePlease observe the following precautions for safe use of the products.(1) Installation Environment Do not use the product in environments where it can be exposed to inflammable/ explosive gas. Install

5、 the Amplifier Unit in such a way that the ventilation holes are not blocked. To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. During installation, make sure that screws are tightened firmly.(2) Power Supply and Wiring The

6、 supply voltage must be within the rated range (DC24V10%). Reverse connection of the power supply is not allowed. Open-collector outputs should not be short-circuited. Use the power supply within the rated load. High-voltage lines and power lines must be wired separately from this product. Wiring th

7、em together or placing them in the same duct may cause induction, resulting in mal- function or damage.(3) Others During installation, make sure that screws are tightened firmly. Do not attempt to dismantle, repair, or modify the product. Dispose of this product as industrial waste. Should you notic

8、e any abnormalities, immediately stop use, turn OFF the power sup- ply, and contact your OMRON representative.Precautions for Safe Use5ZFV Users ManualIntroductionIntroduction Precautions for Correct UsePlease observe the following precautions to prevent failure to operate, malfunctions, orundesirab

9、le effects on product performance.(1) Installation Site Do not install the product in locations subjected to the following conditions: Ambient temperature outside the rating Rapid temperature fluctuations (causing condensation) Relative humidity outside the range of 35 to 85% Presence of corrosive o

10、r flammable gases Presence of dust, salt, or iron particles Direct vibration or shock Reflection of intense light (such as other laser beams or electric arc-welding machines) Direct sunlight or near heaters Water, oil, or chemical fumes or spray Strong magnetic or electric field(2) Power Supply and

11、Wiring When using a commercially available switching regulator, make sure that the FG ter- minal is grounded. If surge currents are present in the power lines, connect surge absorbers that suit the operating environment. Before turning ON the power after the product is connected, make sure that the

12、power supply voltage is correct, there are no incorrect connections (e.g. load short-circuit) and the load current is appropriate. Incorrect wiring may result in breakdown of the product. Before connecting/disconnecting the Sensor Head, make sure that the Smart Sensor is turned OFF. The Smart Sensor

13、 may break down if the Sensor Head is connected or disconnected while the power is ON. Use only combinations of Sensor Heads and Sensor Controllers specified in this man- ual. Do not turn the power OFF in the following instances -Immediately after the MENU mode or ADJ mode is switched to the RUN mod

14、e -During startup in the RUN mode -Wait for the ENABLE signal to turn ON before turning the power OFF as the bank data may be initialized.Precautions for Correct Use6IntroductionZFV Users ManualIntroduction Precautions for Correct Use(3) Orientation when Installing the Amplifier Unit(4) Maintenance

15、and Inspection Do not use thinner, benzene, acetone or kerosene to clean the Sensor Head and Amplifier Unit. If large dust particles adhere to the front Panel of the Sensor Head, use a blower brush (used to clean camera lenses) to blow them off. Do not blow the dust particles with your mouth. To rem

16、ove smaller dust particles, wipe gently with a soft cloth. Do not use excessive force to wipe off dust particles. Scratches on the front Panel may cause errors. (5) Optical Axis and Detection Range The center of the guide light and detection range are for reference only. The center of the optical axis sometimes differs according to each Sensor Head. Dur- ing installat