ap1000术语翻译

上传人:第*** 文档编号:31321717 上传时间:2018-02-06 格式:DOC 页数:5 大小:58.50KB
返回 下载 相关 举报
ap1000术语翻译_第1页
第1页 / 共5页
ap1000术语翻译_第2页
第2页 / 共5页
ap1000术语翻译_第3页
第3页 / 共5页
ap1000术语翻译_第4页
第4页 / 共5页
ap1000术语翻译_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

《ap1000术语翻译》由会员分享,可在线阅读,更多相关《ap1000术语翻译(5页珍藏版)》请在金锄头文库上搜索。

1、Term 术语 Definitions 定义解说Active equipment 有源设备 Equipment which shall perform a mechanical motion as part of its safety-related function. 作为安全相关功能的一部分,进行机械运动的设备。Aging 老化 The effect of operation, environmental and system conditions on equipment during a period of time up to, but not including design ba

2、sis events, or the process of simulating these events. 经过一段时间的使用,设备在环境整体影响下的变化,不包括设备本身基本设计方面的变化。Component 组件 Discrete items from which the equipment is assembled. 组装成设备的离散型零件。Cutoff Frequency 截止频率;切截频率The frequency in the response spectrum where the zero period acceleration asymptote begins. This is

3、 the frequency beyond which single degree of freedom oscillators exhibit no amplification of motion, and indicates the upper limit of the frequency content of the waveform being analyzed. 频率响应谱中的零期渐近开始加速。截止频率是单个自由振荡器在没有继续提速征兆情况下的频数,代表了受分析的波形曲线的上限频率。Damping阻尼器 An energy dissipation mechanism that red

4、uces the amplification and broadens the vibratory response in the region of response. Damping is usually expressed as a percentage of critical damping. Critical damping is defined as the least amount of viscous damping that causes a single degree-of-freedom system to return to its original position

5、without oscillation after initial disturbance. 一种耗减运动能量的装置,通过降低扩增和拓宽振动响应区域来吸能减震。阻尼器的值域通常用临界阻尼的百分比表示。在第一次受力后,来自阻尼器的阻力使振动物流刚能不作周期性振动便能最快地回到平衡职位的情况,称为临界阻尼。 Design Basis Accident (DBA)设计基准事故 Those plant conditions resulting from various postulated equipment and piping failures during which safety-relate

6、d equipment shall operate without impairment of the safety- related function in a harsh environment. A design basis accident is a subset of a design basis event. 在恶劣的环境中,由于各种设备和管道的非安全设计及操作引发的工厂事故工况。设计基准事故是设计基准事变的一种。Design Basis Event (DBE) 设计基准事件Any of the events specified in the stations safety ana

7、lysis that are used to establish the acceptable performance for safety-related functions: events include anticipated transients, design basis accidents, external events, and natural phenomena. 在工厂安全备注中强调的所有状况,用于建立安全功能作业的典范,包括预期瞬变、设计基准事故、外部事故和其他客观自然条件。Design Life 设计寿命 The time during which satisfacto

8、ry performance can be expected for a specific set of service conditions. The design life is established from applicable industry/vendor data to meet the equipment performance requirements. 产品设计时预计不失去使用功能的有效使用时间。设计寿命主要用于工业应用时对设备作业状况要求的描述。Engineered Safeguards Feature (ESF) 工程安全防护特点 A system consistin

9、g of sensors, signal processors, logic, and actuation initiation devices necessary to effect functioning of engineered safeguard features (e.g. emergency feed water containment isolation, emergency core cooling, emergency power), including essential auxiliary systems. 一整套制度规定,包括传感器、信号处理器、逻辑及驱动装置启动运作

10、所需的工程维护功能(如应急给水遏制隔离、堆芯应急冷却、应急能源供应)和其他重要的辅助系统。Equipment 设备: An assembly or subassembly of components designed and manufactured to perform specific function(s). 为了执行特定功能而组装或装配起来的零件集合体。Flexible Equipment柔性设备:Equipment, structures and components whose lowest resonant frequency is less than the cutoff fr

11、equency on the response spectrum. 设备的一种,其结构和组成部分的最低共振频率低于截止频率的反应谱。Floor Acceleration :楼层加速度The acceleration of a particular building floor (or equipment mounting) resulting from the motion of a given earthquake. The maximum floor acceleration is the zero period acceleration of the floor response spe

12、ctrum. 由某一特定地震引发的特定楼层(或安装设备)的加速度。最高楼层加速度是地板反应谱的零期加速度。Harsh Environment :恶劣环境An environment expected as a result of the postulated service conditions appropriate for the design basis and post-design basis accidents of the station. 在适当的假设条件下,由引发事故的设计基础和后设计基础导致的环境。Margin :空缺The difference between servi

13、ce conditions and the conditions to which the equipment is qualified. 服务条件和合格设备服务条件之间的差距。Mild Environment :和缓环境An environment expected as a result of normal service conditions and extremes (abnormal) in-service conditions where seismic is the only design basis event of consequence. 正常的服务条件和来自于抗震设计依据

14、的极端异常的服务条件下的环境。Mission Time :持续运行时间:The amount of time from the initiation of the Design Basis Accident (DBA) that a mechanical equipment component is required to maintain the ability to perform the required safety function. A mechanical equipment component shall maintain the ability to perform the

15、required safety function at any time up to and including the end of its mission time. 从机械设备发生设计基准事故开始到维持必要的安全功能的过程所需要的时间总量。这一机械设备必须拥有可以在任何时间开始履行工程的安全功能,而且必须可以随时停止运转。Natural Frequency :固有频率 The frequency(s), at which body vibrates due to its own physical characteristics (mass and stiffness) when the

16、body is distorted in a specific direction and then released. 当物体被外力送往特定的运动方向而后自由运动时,由其自身的物理特性(重量和刚度)所决定的振动频率。Operating Basis Earthquake (OBE) :运行基准地震An earthquake that could reasonably be expected to occur at the plant site during the operating life of the plant considering the regional and local geology and seismology and specific characteristics of local subsurface material. It is that earthquake that produces the vibratory ground motion for which those feature

展开阅读全文