1、w土木工程建筑外文文献及翻译 Cyclic behavior of steel moment frameconnections under varying axial load and lateraldisplacementsAbstractThis paper discusses the cyclic behavior of four steel moment connections tested under variable axial load and lateral displacements. The beam specim- ens consisted of a reducedbe

2、am section, wing plates and longitudinal stiffeners. The test specimens were subjected to varying axial forces and lateral displace- ments to simulate the effects on beams in a Coupled-Girder Moment-Resisting Framing system under lateral loading. The test results showed that the specim- ens responde

3、d in a ductile manner since the plastic rotations exceeded 0.03 rad without significant drop in the lateral capacity. The presence of the longitudin- al stiffener assisted in transferring the axial forces and delayed the formation of web local buckling.1. Introduction Aimed at evaluating the structu

4、ral performance of reduced-beam section(RBS) connections under alternated axial loading and lateral displacement, four full-scale specimens were tested. These tests were intended to assess the performance of the moment connection design for the Moscone Center Exp- ansion under the Design Basis Earth

5、quake (DBE) and the Maximum Considered Earthquake (MCE). Previous research conducted on RBS moment connections 1,2 showed that connections with RBS profiles can achieve rotations in excess of 0.03 rad. However, doubts have been cast on the quality of the seismic performance of these connections unde

6、r combined axial and lateral loading.The Moscone Center Expansion is a three-story, 71,814 m2 (773,000 ft2) structure with steel moment frames as its primary lateral force-resisting system. A three dimensional perspective illustration is shown in Fig. 1. The overall height of the building, at the hi

7、ghest point of the exhibition roof, is approxima- tely 35.36 m (116ft) above ground level. The ceiling height at the exhibition hall is 8.23 m (27 ft) , and the typical floor-to-floor height in the building is 11.43 m (37.5 ft). The building was designed as type I according to the requi- rements of

8、the 1997 Uniform Building Code.The framing system consists of four moment frames in the EastWest direct- ion, one on either side of the stair towers, and four frames in the NorthSouth direction, one on either side of the stair and elevator cores in the east end and two at the west end of the structu

9、re 4. Because of the story height, the con- cept of the Coupled-Girder Moment-Resisting Framing System (CGMRFS) was utilized.By coupling the girders, the lateral load-resisting behavior of the moment framing system changes to one where structural overturning moments are resisted partially by an axia

10、l compressiontension couple across the girder system, rather than only by the individual flexural action of the girders. As a result, a stiffer lateral load resisting system is achieved. The vertical element that connects the girders is referred to as a coupling link. Coupling links are analogous to

11、 and serve the same structural role as link beams in eccentrically braced frames. Coupling links are generally quite short, having a large shear- to-moment ratio.Under earthquake-type loading, the CGMRFS subjects its girders to wariab- ble axial forces in addition to their end moments. The axial for

12、ces in theFig. 1. Moscone Center Expansion Project in San Francisco, CAgirders result from the accumulated shear in the link.2.Analytical model of CGMRFNonlinear static pushover analysis was conducted on a typical one-bay model of the CGMRF. Fig. 2 shows the dimensions and the various sections of th

13、e 10 in) and the 254 mm (1 1/8 in model. The link flange plates were 28.5 mm 18 3/4 in). The SAP 2000 computer 476 mm (3 /8 in web plate was 9.5 mm program was utilized in the pushover analysis 5. The frame was characterized as fully restrained(FR). FR moment frames are those frames for 1170 which n

14、o more than 5% of the lateral deflections arise from connection deformation 6. The 5% value refers only to deflection due to beamcolumn deformation and not to frame deflections that result from column panel zone deformation 6, 9. The analysis was performed using an expected value of the yield stress

15、 and ultimate strength. These values were equal to 372 MPa (54 ksi) and 518 MPa (75 ksi), respectively. The plastic hinges loaddeformation behavior was approximated by the generalized curve suggested by NEHRP Guidelines for the Seismic Rehabilitation of Buildings 6 as shown in Fig. 3. y was calcu- l

16、ated based on Eqs. (5.1) and (5.2) from 6, as follows: PM hinge loaddeformation model points C, D and E are based on Table 5.4 from 6 for y was taken as 0.01 rad per Note 3 in 6, Table 5.8. Shear hinge load- loaddeformation model points C, D and E are based on Table 5.8 6, Link Beam, Item a. A strain hardening slope between points B and C of 3% of the elastic slope was assumed for both models.Th