MP 270B, TP 270, OP 270_e

上传人:冰*** 文档编号:126085579 上传时间:2020-03-21 格式:PDF 页数:276 大小:2.18MB
返回 下载 相关 举报
MP 270B, TP 270, OP 270_e_第1页
第1页 / 共276页
MP 270B, TP 270, OP 270_e_第2页
第2页 / 共276页
MP 270B, TP 270, OP 270_e_第3页
第3页 / 共276页
MP 270B, TP 270, OP 270_e_第4页
第4页 / 共276页
MP 270B, TP 270, OP 270_e_第5页
第5页 / 共276页
点击查看更多>>
资源描述

《MP 270B, TP 270, OP 270_e》由会员分享,可在线阅读,更多相关《MP 270B, TP 270, OP 270_e(276页珍藏版)》请在金锄头文库上搜索。

1、Preface Contents Introduction 1 Functionality 2 Commissioning 3 Operation 4 Operating Screens and Screen Objects 5 Recipes 6 Archives 7 System Settings 8 Installation 9 Dimensions 10 Options 11 Maintenance Upkeep 12 Operating System Update 13 Appendices A D Glossary Index Release 12 01 A5E00136825 O

2、rder No 6AV6591 1DC20 0AB0 Multi Panel MP 270B Touch Panel TP 270 Operator Panel OP 270 Equipment Manual SIMATIC HMI www PLC Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates a potentially hazardous situation which if not

3、 avoided could result in death or serious injury Caution used with the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Caution used without the safety alert symbol indicates a potentially hazardous situation which if not avo

4、ided may result in property damage Notice indicates that unwanted events or status can occur if the relevant information is not observed Note draws your attention to particularly important information on the product handling the product or to a particular part of the documentation Qualified Personne

5、l Equipment may be commissioned and operated only by qualified personnel Qualified personnel within the meaning of the safety notices in this manual are persons who are authorized to commission ground and iden tify equipment systems and circuits in accordance with safety engeneering standards Correc

6、t Usage Please note the following Warning The device may only be used for the application cases specified in the catalog and the technical description and may only be used in combination with third party equipment and components recommended or approved by Siemens Startup must not take place until it

7、 is established that the machine which is to accommodate this component is conforms with the guideline 98 37 EC Appropriate transport and appropriate storage installation and assembly as well as careful operation and maintenance are required to ensure that the product operates perfectly and safely S

8、afety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are marked as follows according to the level of danger www PLC Trademarks The registered trademarks of the Siemens AG can

9、be found in the preface The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner Impressum Editor and Publisher A display processes machines and systems on full graphic dynamic screens display and edit mess

10、ages and process tags e g in output fields bar graphs trend curves or status displays intervene directly in the running process by input Configuration using ProTool CS Graphics texts user defined functions and operating and display elements which need to be represented on the operating units must fi

11、rst be created on a configuration computer PC or PU using the SIMATIC ProTool CS configuration software In order to download the configuration to the operating units the configuration computer must be connected to it refer to Configuration phase in Figure 1 1 The connection can be established by a s

12、erial an MPI PROFIBUS DP network a USB or an Ethernet interface or via a standard modem path Once the configuration has been successfully downloaded connect the operating unit to the PLC The operating unit can then communicate with the PLC and respond according to the information configured for runn

13、ing the program in the PLC refer to Process running phase in Figure 1 1 Create project data Save project data Test the configuration Simulate configuration Download project data Connected to PLC Configuration phase PC PU PLC Operating unit Process running phase Figure 1 1Configuration and process ru

14、nning phase www PLC IntroductionRelease 12 01 1 4 Multi Panel MP 270B Touch Panel TP 270 Operator Panel OP 270 Equipment Manual 6AV6591 1DC20 0AB0 Overview MP 270B OP 270 10 and TP 270 10 FeaturesMP 270B Key MP 270B Touch OP 270 10 TP 270 10 ProcessorType64 bit RISC CPU Configuration memory Capacity

15、 max 4 MByte2 MByte SoftwareOperating systemMicrosoft Windows CE InterfacesStandard HMI interfaces for connection to PLC PC PU and printer 1 RS 232 1 RS 232 9 pin 1 RS 422 RS 485 Interfaces S7 connectionMPI PROFIBUS DP Interfaces Further interfaces for network external keyboard and mouse 1 Ethernet

16、10 100 Mbit 1 USB 12 Mbaud Host 1 USB 12 Mbaud Host Color displayTypeTFT LCDTFT LCD with touch panel CSTN LCDCSTN LCD with touch panel Color display Active screen diagonal10 4 Color display Resolution pixels 640 480 VGA Color display Possible colors256 Color display Back lightingCCFL tube Service life approx h 50 00060 000 Membrane keyboard System keys with dedicated functions 38 3 with LEDs 38 3 with LEDs Membrane keyboard Function keys with configurable functions 36 28 with LEDs 36 28 with LED

展开阅读全文
相关资源
正为您匹配相似的精品文档
相关搜索

最新文档


当前位置:首页 > 行业资料 > 公共安全/评价

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号