1、MASTER CONTRACT: 218317 REPORT: 1965853 PROJECT: 1965853 Edition 1:June 28, 2007; Project 1965853 TorontoPrepared by Contents:Certificate of Compliance - Page 1 Supplement to Certificate of Compliance - Page 1Descriptive Report and Test Results - Pages 1 to 80Illustrations - Ills 1 to 9Figures - Fig

2、s 1 to 14Attachment - Atts. A and BPRODUCTSCLASS 1211 05 - COMFORT CONDITIONING EQUIPMENT (ELECTRICAL) Air ConditionersCLASS 1211 85 - COMFORT CONDITIONING EQUIPMENT (ELECTRICAL) -CERTIFIED TO U.S. STANDARDSCentral Air Conditioners, ducted unit, permanently connected, consisting of an air cooled out

3、door unit and a matching indoor unit, using refrigerant R410A, with model numbers and ratings shown as follows:PART A:Outdoor unit, BORA Model 24CHSRA, rated 208/230V, 60Hz, 1 phase.PART B:Outdoor unit, BORA Model 30CHSRA, rated 208/230V, 60Hz, 1 phase.PART C:Indoor unit, CARRIER Model FE4ANF005, ra

4、ted 208/230V, 60Hz, 1 phase.APPLICABLE REQUIREMENTSCAN/CSA-C22.2 No.236-05-Heating and Cooling Equipment.UL Standad No.1995-Heating and Cooling Equipment.MARKINGSINDOOR UNIT: Not applicable. The indoor unit is an UL listed fan coil unit and is marked in accordance with UL certification report.OUTDOO

5、R UNIT: A CSA Accepted or UL Recognized adhesive type nameplate Certified for outdoor use, is affixed to the outside of the cabinet bears the submittors name or file number 218317, model designation, date of manufacture, complete electrical rating in volts, hertz, number of phases, input ampere rati

6、ng of each fan motors, RLA and LRA of the compressor, minimum circuit ampacity, Max. Over current Protection (Fuse or HACR Type Circuit Breaker): A”, quantity and type of refrigerant, the design high and low side pressures, and the CSA Monogram with the “C US” indicator.Caution Wording: WARNING: RIS

7、K OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH:DISCONNECT ALL REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING. AVERTISSEMENT. RISQUE DE CHOCS ELECTRIQUES.PEUT CAUSER DES BLESSURES ET MEME ENTRAINER LA MORT. COUPER LES SOURCES DALIMENTATION A DISTANCE AVANT LE DEPANNAGE.The above caution wording may

8、appear on a separate adhesive type nameplate affixed near to the main nameplate. Labels not affixed to removable cover unless otherwise specified.USE COPPER SUPPLY WIRES. UTILISER DES FILS DALIMENTATION EN CUIVREThe above caution wording appears on a separate adhesive type label near the main termin

9、al block.The statement “for use with indoor unit, CARRIER MODEL FE4ANF005”.Suitable wiring diagram is provided on each unit (paper wiring diagram is affixed to the access panel inside surface).Suitable wiring diagram is provided on the unit.Installation operating manual is provided with each outdoor

10、 unit.Notes: 1. Jurisdictions in Canada may require these markings to be also in French. It is the responsibility of the customer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities.2. The product may bear the CSA logo, or CSA

11、with US indicator, or CSA with C US indicator.ALTERATIONS1. The markings are as noted above.FACTORY TESTS409613868. Dielectric Withstand Test: The equipment, upon completion of manufacture and before shipment, shall withstand, for not less than one second, without breakdown, the application of the f

12、ollowing ac voltages, between live parts and exposed metal parts:(a)1,000V for units with a motor rated at less than 1/2 hp and rated 250V or less.(b)1,000V plus twice rated voltage for all other units.For units which include extra-low-potential circuits (30V or less), the test is to be conducted wi

13、th the extra-low-potential circuit connected to the cabinet, chassis, or other dead metal part, so that the potential which is applied between the primary circuit and the exposed metal parts, is applied simultaneously between the primary circuit and the extra-low-potential circuit.(c)For units which

14、 include extra-low-potential circuits; 500V between the extra-low-potential circuit and exposed metal parts.Note: The test specified in Item (c) may be waived, if the extra-low-potential circuit is grounded or Class 2.409613869. Pressure Test for Refrigerant Leakage: At the completion of manufacture

15、 and before shipment, the complete refrigeration system of the equipment shall be tested and proved tight at pressures not less than the highest of the following:(a)The design pressures marked on the data plate for the device.(b)The minimum test pressures tabulated below.RefrigerantMinimum Design Pressure*Low SideHigh SidekPapsigkPapsig229931441917278500703102140020350211171622082302134a593861282186R407C11421662191318R410A16222353075446Notes:*A method othe