1、0本科毕业设计外文文献及译文文献、资料题目:Estimates of the Operational Reliability of Fire Protection Systems文献、资料来源:网络文献、资料发表(出版)日期:2008.6院 (部): 市政与环境工程学院专 业: 给水排水工程班 级: 姓 名: 学 号: 指导教师: 翻译日期: 2008.6Times New Roman,小4号,1.5倍行距页眉:黑体,5号,居中外文文献:Estimates of the Operational Reliability of Fire Protection SystemsFor the past

2、 three years,the National Institute of Standards and Technology (NIST) has been working to develop a new encryption standard to keep government information secureThe organization is in the final stages of an open process of selecting one or more algorithms,or data-scrambling formulas,for the new Adv

3、anced Encryption Standard (AES) and plans to make adecision by late summer or early fallThe standard is slated to go into effect next year Richard W. Bukowski, P.E. Senior Engineer MST Building and Fire Research Laboratory Gaithersburg, MD 20899-8642 USA Edward K. Budnick, P.E., and Christopher F. S

4、cheme1 Vice President Chemical Engineer Hughes Associates, Inc Hughes Associates, Inc. Baltimore, MD 21227-1652USA Baltimore, MD 2 1227-1652USA INTRODUCTION Background Fire protection strategies are designed and installed to perform specific functions. For example, a fire sprinkler system is expecte

5、d to control or extinguish fires: To accomplish this, the system sprinklers must open, and the required amount of water to achieve control or extinguishment must be delivered to the fire location. A fire detection system is intended to provide sufficient early warning of a fireto permit occupant not

6、ification and escape, fire servicenotification, and in some cases activation of other fire protection features (e.g., special extinguishing systems, smoke management systems). Both system activation (detection) and notification (alarm) must occur to achieve early warning. Construction compartmentati

7、on is generally designed to limit the extent of fire spread as well as to maintain the buildings structural integrity as well as tenability along escape routes for some specified period of time. In order to accomplish this, the construction features must be fire “rated” (based on standard tests) and

8、 the integrity of the features maintained. The reliability of individual fire protection strategies such as detection, automatic suppression, and construction compartmentation is important input to detailed engineering analyses associated with performance based design. In the context of safety syste

9、ms, there are several elements of reliability, including both operational andperfornzance reliability. Operational reliability provides a measure of the probability that a fire protection system will operate as intended when needed. Performance reliability is a measure of the adequacy of the feature

10、 to successfully perform its intended hnction under specific fire exposure conditions. The former is a measure of component or system operability while the latter is a measure of the adequacy of the system design. The scope of this study was limited to evaluation of operational reliability due prima

11、rily to the form of the reported data in the literature. In addition to this distinction between operational and performance reliability, the scope focused on unconditional estimates of reliability and failure estimates in terms offail-dangerous outcomes. A discussion of these terms is provided late

12、r in the paper. Scop This paper provides a review of reported operational reliability and performance estimates for (1) fire detection, (2) automatic suppression, and to a limited extent (3) construction compartmentation. In general, the reported estimates for fire detection are largely for smoke de

13、tectiodfire alarm systems; automatic sprinklers comprise most of the data for automatic suppression, and compartmentation includes compartment fire resistance and enclosure integrity. It should be noted that in some cases the literature did not delineate beyond the general categories of “fire detect

14、ion” or “automatic suppression,” requiring assumptions regarding the specific type of fire protection system. Several studies reported estimates of reliability for both fire detection and automatic sprinkler system strategies. However, very little information was found detailing reliability estimate

15、s for passive fire protection strategies such as compartmentation. A limited statistical based analysis was performed to provide generalized information on the ranges of such estimates and related uncertainties. This latter effort was limited to evaluation of reported data on detection and suppression. Insufficient data were identified on compartmentation reliability to be included.