心脏电生理技术基础(膜片钳)讲解

上传人:我** 文档编号:113748490 上传时间:2019-11-09 格式:PPT 页数:52 大小:3.05MB
返回 下载 相关 举报
心脏电生理技术基础(膜片钳)讲解_第1页
第1页 / 共52页
心脏电生理技术基础(膜片钳)讲解_第2页
第2页 / 共52页
心脏电生理技术基础(膜片钳)讲解_第3页
第3页 / 共52页
心脏电生理技术基础(膜片钳)讲解_第4页
第4页 / 共52页
心脏电生理技术基础(膜片钳)讲解_第5页
第5页 / 共52页
点击查看更多>>
资源描述

《心脏电生理技术基础(膜片钳)讲解》由会员分享,可在线阅读,更多相关《心脏电生理技术基础(膜片钳)讲解(52页珍藏版)》请在金锄头文库上搜索。

1、CELLULAR CARDIAC ELECTROPHYSIOLOGICAL TECHNIQUES,NORBERT JOST, PhD,Electrical model of the membrane Standard intracellular microelectrode technique Voltage clamp technique Patch clamp technique,G=1/R,Ohms law,Ion channel model,Current clamp,Voltage clamp,Intracellular microelectrode technique,Re Rin

2、 Rin = 1012 Ohm,0.1 - 0.2 m,Ag/AgCl 3 M KCl,Re 10 - 40 MOhm,The setup,Organ bath,d: stimulating electrode,e: microelectrode,r: referent electrode,P: preparation,computer,A/D,ingerl,amplifier,Detected signal,P,d,e,r,100 ms,50 mV,0mV,drug,60 min,20-60 min,60 min,0 mV,APA,RP,APD50,APD90,90%,50%,Vmax,Wa

3、sh-out,Pre-incubation,Two microelectrode voltage clamp,voltage command,holding potential,test potential,The macroscopic sodium current,The voltage-clamp circuit,voltage command,amplifier,Current measure,voltage measure,follow up amplifier,Patch-clamp: the special case of the voltage clamp,Cell,Patch

4、-clamp: the special case of the voltage clamp,(1) Suck a small piece of membrane onto the tip of a glass micropipette ( 1 m in diameter),Cell,(2) “Gigaohm-seal”,R 1 GOhm,Patch-clamp: the special case of the voltage clamp,Cell,(3) Sense voltage here, inside the electrode, and use voltage clamp to kee

5、p it constant.,Patch-clamp: the special case of the voltage clamp,closed open,Cell,+ +,Patch-clamp: the special case of the voltage clamp,(3) Sense voltage here, inside the electrode, and use voltage clamp to keep it constant.,closed open open,Cell,(3) Turn on the aimed potential the inside part of

6、the pipette and keep it constantly by applying the voltage clamp technique.,Patch-clamp: the special case of the voltage clamp,voltage command,10 msec,Properties of individual voltage-dependent sodium channels,Individual channels are either open or closed (no partial openings),Properties of individu

7、al voltage-dependent sodium channels,Individual channels are either open or closed (no partial openings) Each channel opening is only a brief event compared to the total duration of the whole cell voltage-dependent sodium current.,The macroscopic sodium current,Properties of individual voltage-depen

8、dent sodium channels,Individual channels are either open or closed (no partial openings) Each channel opening is only a brief event compared to the total duration of the whole cell voltage-dependent sodium current. Channel opening and closing is variable in duration and latency.,Properties of indivi

9、dual voltage-dependent sodium channels,The macroscopic sodium current,The channels are either in open or closed state. The channel openings are short events when compared with the macroscopic sodium current. The time duration and latency of the channel openings are variable (case sensitive). Might h

10、appen to not open at all. The open probability of the channels resembles with that of the macroscopic current.,Properties of individual voltage-dependent sodium channels,The macroscopic sodium current,Summation of 300 recordings,Individual channels are either open or closed (no partial openings) Eac

11、h channel opening is only a brief event compared to the total duration of the whole cell voltage-dependent sodium current. Channel opening and closing is variable in duration and latency. The overall probability of channel opening is similar to the total sodium current. Look at the sum of the curren

12、ts from 300 trials. Sometimes an individual channel doesnt open even once.,Summation of 300 recordings,Properties of individual voltage-dependent sodium channels,The macroscopic sodium current,Individual channels are either open or closed (no partial openings) Each channel opening is only a brief ev

13、ent compared to the total duration of the whole cell voltage-dependent sodium current. Channel opening and closing is variable in duration and latency. The overall probability of channel opening is similar to the total sodium current. Look at the sum of the currents from 300 trials. Sometimes an ind

14、ividual channel doesnt open even once. Second openings are rare (because of inactivation),Summation of 300 recordings,Properties of individual voltage-dependent sodium channels,The macroscopic sodium current,Slowly inactivating K current channel (Ram & Dagan, 1987),Individual channels are either open or closed (no partial openings). Sometimes more than one channel is in a

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 高等教育 > 大学课件

电脑版 |金锄头文库版权所有
经营许可证:蜀ICP备13022795号 | 川公网安备 51140202000112号